... ... @@ -229,7 +229,7 @@
229 229  
230 230  The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage.
231 231  
232 -Calculated currents values are sending to chargers or intellectual loads over the CAN bus.
232 +Calculated currents values are sending to chargers over the CAN bus.
233 233  
234 234  To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map":
235 235  
... ... @@ -242,7 +242,7 @@
242 242  * Limit charging current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and temperature;
243 243  * Limit charging current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on the contactor temperature;
244 244  * Limit charging current by the maximum cell voltage – a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage;
245 -* Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on maximum cell temperature.
245 +* Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on cell temperature.
246 246  
247 247  Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows:
248 248  
... ... @@ -252,7 +252,7 @@
252 252  
253 253  The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage.
254 254  
255 -Calculated currents values are sending to chargers or intellectual loads over the CAN bus.
255 +Calculated currents values are sending or intellectual loads over the CAN bus.
256 256  
257 257  To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map":
258 258  
... ... @@ -266,7 +266,7 @@
266 266  * Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature;
267 267  * Limit discharging current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on the contactor temperature;
268 268  * Limit discharging current by the maximum cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on maximum cell voltage;
269 -* Limit discharging current by the maximum cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on maximum cell temperature .
269 +* Limit discharging current by the maximum cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on cell temperature .