Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -229,7 +229,7 @@ 229 229 230 230 The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 231 231 232 -Calculated currents values are sending to chargers o r intellectual loads over the CAN bus.232 +Calculated currents values are sending to chargers over the CAN bus. 233 233 234 234 To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 235 235 ... ... @@ -242,7 +242,7 @@ 242 242 * Limit charging current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and temperature; 243 243 * Limit charging current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on the contactor temperature; 244 244 * Limit charging current by the maximum cell voltage – a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage; 245 -* Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on maximumcell temperature.245 +* Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on cell temperature. 246 246 247 247 Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: 248 248 ... ... @@ -252,7 +252,7 @@ 252 252 253 253 The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 254 254 255 -Calculated currents values are sending tochargersorintellectual loads over the CAN bus.255 +Calculated currents values are sending or intellectual loads over the CAN bus. 256 256 257 257 To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 258 258 ... ... @@ -266,7 +266,7 @@ 266 266 * Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature; 267 267 * Limit discharging current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on the contactor temperature; 268 268 * Limit discharging current by the maximum cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on maximum cell voltage; 269 -* Limit discharging current by the maximum cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on maximumcell temperature .269 +* Limit discharging current by the maximum cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on cell temperature . 270 270 271 271 Value of the discharge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: 272 272