Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,7 +2,7 @@ 2 2 3 3 To change the default cell settings, select the menu "Cells → Cell defaults": 4 4 5 -[[ Cell default section>>image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]]5 +[[image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]] 6 6 7 7 In this section: 8 8 ... ... @@ -31,7 +31,7 @@ 31 31 32 32 To change the parameters of the algorithm for calculating the battery SOC, select the menu "Cells → SOC estimation": 33 33 34 -[[ SOC estimation section>>image:1732206031847-819.png||data-xwiki-image-style-alignment="center" height="849" width="356"]]34 +[[image:1732206031847-819.png||data-xwiki-image-style-alignment="center" height="849" width="356"]] 35 35 36 36 In this section: 37 37 ... ... @@ -81,7 +81,7 @@ 81 81 82 82 To change parameters of the algorithm for calculating the cell resistance, select the menu "Cells → Cell resistance estimation": 83 83 84 -[[ Cell resistance estimation settings>>image:1732207338609-903.png||data-xwiki-image-style-alignment="center" height="187" width="337"]]84 +[[image:1732207338609-903.png||data-xwiki-image-style-alignment="center" height="187" width="337"]] 85 85 86 86 In this section: 87 87 ... ... @@ -119,7 +119,7 @@ 119 119 120 120 To change the cell balancing parameters, select the menu "Cell → Cell balancing": 121 121 122 -[[ Cell balancing settings>>image:1732207485773-804.png||data-xwiki-image-style-alignment="center" height="264" width="387"]]122 +[[image:1732207485773-804.png||data-xwiki-image-style-alignment="center" height="264" width="387"]] 123 123 124 124 In this section: 125 125 ... ... @@ -151,7 +151,7 @@ 151 151 152 152 To change the series balancing parameters, select the menu "Cell → Series balancing": 153 153 154 -[[ Series balancing settings>>image:1732207584941-447.png||data-xwiki-image-style-alignment="center" height="258" width="438"]]154 +[[image:1732207584941-447.png||data-xwiki-image-style-alignment="center" height="258" width="438"]] 155 155 156 156 In this section: 157 157 ... ... @@ -176,7 +176,7 @@ 176 176 177 177 To configure parameters for determining the discharge characteristic of the battery, select the menu "Cells → Cell analysis": 178 178 179 -[[ Cell analysis section>>image:1732207696322-587.png||data-xwiki-image-style-alignment="center" height="213" width="258"]]179 +[[image:1732207696322-587.png||data-xwiki-image-style-alignment="center" height="213" width="258"]] 180 180 181 181 In this section: 182 182 ... ... @@ -229,11 +229,11 @@ 229 229 230 230 The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 231 231 232 -Calculated currents values are sending to chargers o r intellectual loads over the CAN bus.232 +Calculated currents values are sending to chargers over the CAN bus. 233 233 234 234 To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 235 235 236 -[[ Charge current map settings>>image:1732208033738-498.png||data-xwiki-image-style-alignment="center" height="655" width="453"]]236 +[[image:1732208033738-498.png||data-xwiki-image-style-alignment="center" height="655" width="453"]] 237 237 238 238 In this section: 239 239 ... ... @@ -242,7 +242,7 @@ 242 242 * Limit charging current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and temperature; 243 243 * Limit charging current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on the contactor temperature; 244 244 * Limit charging current by the maximum cell voltage – a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage; 245 -* Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on maximumcell temperature.245 +* Limit charging current by the maximum cell temperature – a flag to enable correction of maximum allowable charging current Kct depending on cell temperature. 246 246 247 247 Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: 248 248 ... ... @@ -252,11 +252,11 @@ 252 252 253 253 The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 254 254 255 -Calculated currents values are sending tochargersorintellectual loads over the CAN bus.255 +Calculated currents values are sending or intellectual loads over the CAN bus. 256 256 257 257 To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 258 258 259 -[[ Discharge currentmap settings>>image:1732208218667-968.png||data-xwiki-image-style-alignment="center" height="631" width="434"]]259 +[[image:1732208218667-968.png||data-xwiki-image-style-alignment="center" height="631" width="434"]] 260 260 261 261 In this section: 262 262 ... ... @@ -266,7 +266,7 @@ 266 266 * Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature; 267 267 * Limit discharging current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on the contactor temperature; 268 268 * Limit discharging current by the maximum cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on maximum cell voltage; 269 -* Limit discharging current by the maximum cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on maximumcell temperature .269 +* Limit discharging current by the maximum cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on cell temperature . 270 270 271 271 Value of the discharge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: 272 272 ... ... @@ -278,7 +278,7 @@ 278 278 279 279 To configure parameters for periodically correcting the battery state of charge, select the menu "Cells → SOC correction": 280 280 281 -[[ SOC correction settings>>image:1732206262509-786.png||data-xwiki-image-style-alignment="center" height="291" width="298"]]281 +[[image:1732206262509-786.png||data-xwiki-image-style-alignment="center" height="291" width="298"]] 282 282 283 283 In this section: 284 284