Changes for page 3.4 Battery parameters

Last modified by Admin on 2025/04/09 12:04

From version 12.1
edited by Admin
on 2024/11/21 17:00
Change comment: There is no comment for this version
To version 14.1
edited by Admin
on 2024/11/28 12:48
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.bms-main-2-1.configuration.WebHome
1 +drafts.bms-main-2.configuration.WebHome
Content
... ... @@ -2,7 +2,7 @@
2 2  
3 3  To change the default cell settings, select the menu "Cells → Cell defaults":
4 4  
5 -[[Cell default section>>image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]]
5 +[[image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]]
6 6  
7 7   In this section:
8 8  
... ... @@ -31,7 +31,7 @@
31 31  
32 32  To change the parameters of the algorithm for calculating the battery SOC, select the menu "Cells → SOC estimation":
33 33  
34 -[[SOC estimation section>>image:1732206031847-819.png||data-xwiki-image-style-alignment="center" height="849" width="356"]]
34 +[[image:1732206031847-819.png||data-xwiki-image-style-alignment="center" height="849" width="356"]]
35 35  
36 36  In this section:
37 37  
... ... @@ -81,7 +81,7 @@
81 81  
82 82  To change parameters of the algorithm for calculating the cell resistance, select the menu "Cells → Cell resistance estimation":
83 83  
84 -[[Cell resistance estimation settings>>image:1732207338609-903.png||data-xwiki-image-style-alignment="center" height="187" width="337"]]
84 +[[image:1732207338609-903.png||data-xwiki-image-style-alignment="center" height="187" width="337"]]
85 85  
86 86  In this section:
87 87  
... ... @@ -119,7 +119,7 @@
119 119  
120 120  To change the cell balancing parameters, select the menu "Cell → Cell balancing":
121 121  
122 -[[Cell balancing settings>>image:1732207485773-804.png||data-xwiki-image-style-alignment="center" height="264" width="387"]]
122 +[[image:1732207485773-804.png||data-xwiki-image-style-alignment="center" height="264" width="387"]]
123 123  
124 124  In this section:
125 125  
... ... @@ -151,7 +151,7 @@
151 151  
152 152  To change the series balancing parameters, select the menu "Cell → Series balancing":
153 153  
154 -[[Series balancing settings>>image:1732207584941-447.png||data-xwiki-image-style-alignment="center" height="258" width="438"]]
154 +[[image:1732207584941-447.png||data-xwiki-image-style-alignment="center" height="258" width="438"]]
155 155  
156 156  In this section:
157 157  
... ... @@ -176,7 +176,7 @@
176 176  
177 177  To configure parameters for determining the discharge characteristic of the battery, select the menu "Cells → Cell analysis":
178 178  
179 -[[Cell analysis section>>image:1732207696322-587.png||data-xwiki-image-style-alignment="center" height="213" width="258"]]
179 +[[image:1732207696322-587.png||data-xwiki-image-style-alignment="center" height="213" width="258"]]
180 180  
181 181  In this section:
182 182  
... ... @@ -229,11 +229,11 @@
229 229  
230 230  The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage.
231 231  
232 -Calculated currents values are sending to chargers or intellectual loads over the CAN bus.
232 +Calculated currents values are sending to chargers over the CAN bus.
233 233  
234 234  To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map":
235 235  
236 -[[Charge current map settings>>image:1732208033738-498.png||data-xwiki-image-style-alignment="center" height="655" width="453"]]
236 +[[image:1732208033738-498.png||data-xwiki-image-style-alignment="center" height="655" width="453"]]
237 237  
238 238  In this section:
239 239  
... ... @@ -252,11 +252,11 @@
252 252  
253 253  The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage.
254 254  
255 -Calculated currents values are sending to chargers or intellectual loads over the CAN bus.
255 +Calculated currents values are sending or intellectual loads over the CAN bus.
256 256  
257 257  To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map":
258 258  
259 -[[Discharge current map settings>>image:1732208218667-968.png||data-xwiki-image-style-alignment="center" height="631" width="434"]]
259 +[[image:1732208218667-968.png||data-xwiki-image-style-alignment="center" height="631" width="434"]]
260 260  
261 261  In this section:
262 262  
... ... @@ -278,7 +278,7 @@
278 278  
279 279  To configure parameters for periodically correcting the battery state of charge, select the menu "Cells → SOC correction":
280 280  
281 -[[SOC correction settings>>image:1732206262509-786.png||data-xwiki-image-style-alignment="center" height="291" width="298"]]
281 +[[image:1732206262509-786.png||data-xwiki-image-style-alignment="center" height="291" width="298"]]
282 282  
283 283   In this section:
284 284