Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -drafts.bms-main-2 -1.configuration.WebHome1 +drafts.bms-main-2.configuration.WebHome - Content
-
... ... @@ -2,7 +2,7 @@ 2 2 3 3 To change the default cell settings, select the menu "Cells → Cell defaults": 4 4 5 -[[ Cell default section>>image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]]5 +[[image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]] 6 6 7 7 In this section: 8 8 ... ... @@ -31,7 +31,7 @@ 31 31 32 32 To change the parameters of the algorithm for calculating the battery SOC, select the menu "Cells → SOC estimation": 33 33 34 -[[ SOC estimation section>>image:1732206031847-819.png||data-xwiki-image-style-alignment="center" height="849" width="356"]]34 +[[image:1732206031847-819.png||data-xwiki-image-style-alignment="center" height="849" width="356"]] 35 35 36 36 In this section: 37 37 ... ... @@ -81,7 +81,7 @@ 81 81 82 82 To change parameters of the algorithm for calculating the cell resistance, select the menu "Cells → Cell resistance estimation": 83 83 84 -[[ Cell resistance estimation settings>>image:1732207338609-903.png||data-xwiki-image-style-alignment="center" height="187" width="337"]]84 +[[image:1732207338609-903.png||data-xwiki-image-style-alignment="center" height="187" width="337"]] 85 85 86 86 In this section: 87 87 ... ... @@ -119,7 +119,7 @@ 119 119 120 120 To change the cell balancing parameters, select the menu "Cell → Cell balancing": 121 121 122 -[[ Cell balancing settings>>image:1732207485773-804.png||data-xwiki-image-style-alignment="center" height="264" width="387"]]122 +[[image:1732207485773-804.png||data-xwiki-image-style-alignment="center" height="264" width="387"]] 123 123 124 124 In this section: 125 125 ... ... @@ -151,7 +151,7 @@ 151 151 152 152 To change the series balancing parameters, select the menu "Cell → Series balancing": 153 153 154 -[[ Series balancing settings>>image:1732207584941-447.png||data-xwiki-image-style-alignment="center" height="258" width="438"]]154 +[[image:1732207584941-447.png||data-xwiki-image-style-alignment="center" height="258" width="438"]] 155 155 156 156 In this section: 157 157 ... ... @@ -176,7 +176,7 @@ 176 176 177 177 To configure parameters for determining the discharge characteristic of the battery, select the menu "Cells → Cell analysis": 178 178 179 -[[ Cell analysis section>>image:1732207696322-587.png||data-xwiki-image-style-alignment="center" height="213" width="258"]]179 +[[image:1732207696322-587.png||data-xwiki-image-style-alignment="center" height="213" width="258"]] 180 180 181 181 In this section: 182 182 ... ... @@ -229,11 +229,11 @@ 229 229 230 230 The BMS Main 2.x board calculates maximum allowable charge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 231 231 232 -Calculated currents values are sending to chargers o r intellectual loads over the CAN bus.232 +Calculated currents values are sending to chargers over the CAN bus. 233 233 234 234 To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 235 235 236 -[[ Charge current map settings>>image:1732208033738-498.png||data-xwiki-image-style-alignment="center" height="655" width="453"]]236 +[[image:1732208033738-498.png||data-xwiki-image-style-alignment="center" height="655" width="453"]] 237 237 238 238 In this section: 239 239 ... ... @@ -252,12 +252,26 @@ 252 252 253 253 The BMS Main 2.x board calculates maximum allowable discharge current values in respect to SOC and battery temperature, contactor temperature and maximum cell voltage. 254 254 255 -Calculated currents values are sending tochargersorintellectual loads over the CAN bus.255 +Calculated currents values are sending or intellectual loads over the CAN bus. 256 256 257 257 To configure parameters for determining the charge current limit, select the menu "Cells → Charge current map": 258 258 259 -[[image:1732208218667-968.png]] 259 +[[image:1732208218667-968.png||data-xwiki-image-style-alignment="center" height="631" width="434"]] 260 260 261 +In this section: 262 + 263 +* Enable – a flag to start calculation of the discharge current limit; 264 +* Maximum discharging current – a maximum allowable value of the discharge current (under normal conditions): 265 +* Current factor – the dependence of the correction factor on SOC and the battery temperature – Kdischarge=Kdischarge (SOC, t°C). 266 +* Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature; 267 +* Limit discharging current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on the contactor temperature; 268 +* Limit discharging current by the maximum cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on maximum cell voltage; 269 +* Limit discharging current by the maximum cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on maximum cell temperature . 270 + 271 +Value of the discharge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: 272 + 273 +Discharging current limit = Maximum discharging current × Kds × Kdc × Kdv × Kdt. 274 + 261 261 == 3.4.9 SOC correction == 262 262 263 263 The BMS Main 2.x board can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see section Calculating the state of charge (SOC)). ... ... @@ -264,7 +264,7 @@ 264 264 265 265 To configure parameters for periodically correcting the battery state of charge, select the menu "Cells → SOC correction": 266 266 267 -[[ SOC correction settings>>image:1732206262509-786.png||data-xwiki-image-style-alignment="center" height="291" width="298"]]281 +[[image:1732206262509-786.png||data-xwiki-image-style-alignment="center" height="291" width="298"]] 268 268 269 269 In this section: 270 270