2 2  
3 3  To change the default cell settings, select the menu "Cells → Cell defaults":
4 4  
5 -
5 +[[Cell default section>>image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]]
6 +
7 + In this section:
8 +
9 +* Capacity – nominal capacity of cells, Ah;
10 +* Resistance – nominal (maximum) internal resistance of the cell, Ohm;
11 +* Relax time (after charging) – a relaxation time after charging, second;
12 +* Relax time (atfer discharging) – the relaxation time after discharging, second;
13 +* Cycles – a number of charge-discharge cycles;
14 +* Reset battery cycles – a command to reset charge-discharge cycles;
15 +* Reset cell parameters (SOC, capacity, resistance) – a command to reset cells state of charge, capacity, and resistance.
16 +
17 +The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and battery.
18 +
19 +The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery.
20 +
21 +The “Reset cell parameters” command is used for starting-up and adjustment of battery.
22 +