Changes for page 3.4 Battery parameters
Last modified by Admin on 2025/04/09 12:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,4 +2,22 @@ 2 2 3 3 To change the default cell settings, select the menu "Cells → Cell defaults": 4 4 5 - 5 +[[Cell default section>>image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]] 6 + 7 + In this section: 8 + 9 +* Capacity – nominal capacity of cells, Ah; 10 +* Resistance – nominal (maximum) internal resistance of the cell, Ohm; 11 +* Relax time (after charging) – a relaxation time after charging, second; 12 +* Relax time (atfer discharging) – the relaxation time after discharging, second; 13 +* Cycles – a number of charge-discharge cycles; 14 +* Reset battery cycles – a command to reset charge-discharge cycles; 15 +* Reset cell parameters (SOC, capacity, resistance) – a command to reset cells state of charge, capacity, and resistance. 16 + 17 +The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and battery. 18 + 19 +The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery. 20 + 21 +The “Reset cell parameters” command is used for starting-up and adjustment of battery. 22 + 23 +3.4.2 SOC
- 1732205873121-893.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.0 KB - Content