Wiki source code of 3.4 Battery parameters
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | == 3.4.1 Cell defaults == | ||
| 2 | |||
| 3 | To change the default cell settings, select the menu "Cells → Cell defaults": | ||
| 4 | |||
| 5 | [[Cell default section>>image:1732205873121-893.png||data-xwiki-image-style-alignment="center" height="313" width="416"]] | ||
| 6 | |||
| 7 | In this section: | ||
| 8 | |||
| 9 | * Capacity – nominal capacity of cells, Ah; | ||
| 10 | * Resistance – nominal (maximum) internal resistance of the cell, Ohm; | ||
| 11 | * Relax time (after charging) – a relaxation time after charging, second; | ||
| 12 | * Relax time (atfer discharging) – the relaxation time after discharging, second; | ||
| 13 | * Cycles – a number of charge-discharge cycles; | ||
| 14 | * Reset battery cycles – a command to reset charge-discharge cycles; | ||
| 15 | * Reset cell parameters (SOC, capacity, resistance) – a command to reset cells state of charge, capacity, and resistance. | ||
| 16 | |||
| 17 | The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and battery. | ||
| 18 | |||
| 19 | The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery. | ||
| 20 | |||