Wiki source code of 3.3 Cells state
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | == 3.3.1 Cell overview == | ||
| 2 | |||
| 3 | To display the minimum and maximum temperature and voltage of the cells, select the menu “Logic / Cell → Overview”: | ||
| 4 | |||
| 5 | [[Logic and cell overview section>>image:1732201251933-291.png||data-xwiki-image-style-alignment="center" height="312" width="446"]] | ||
| 6 | |||
| 7 | In this section: | ||
| 8 | |||
| 9 | * BMS Logic board parameters: | ||
| 10 | ** Minimum board temperature, °C; | ||
| 11 | ** Maximum board temperature, °C; | ||
| 12 | ** Command rate – rate of data exchange with BMS Logic boards, commands per second; | ||
| 13 | * Cell parameters: | ||
| 14 | ** Minimum cell temperature, °C; | ||
| 15 | ** Maximum cell temperature, °C; | ||
| 16 | ** Minimum cell voltage, V; | ||
| 17 | ** Maximum cell voltage, V. | ||
| 18 | |||
| 19 | After the temperature and voltage values, the symbols "@" indicate the address of the BMS Logic board and the cell. |