Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -114,36 +114,11 @@ 114 114 * System consumption (current offset) – consumption of the BMS system from the battery, A; This setting is used to adjust the current sensor; 115 115 * Set sensor zero level – command set the zero level of the current sensor (used for service purposes). 116 116 117 -(% class="box infomessage" %) 118 -((( 119 -If the "Sensor type" is selected, the “Nominal current” and “Sensitivity” fields are automatically filled. 120 -If the "Sensor type" has no necessary preset, the “Nominal current” and “Sensitivity” parameters must be **manually **entered. 121 -))) 122 122 123 - Calibration of thecurrentsensor(“Calibrate sensoronstartup” flag) is necessaryifthesensordoesnothavea referenceline(zerolevelsignal).118 +If the Sensor type is selected, the “Nominal current” and “Sensitivity” fields are automatically filled. 124 124 125 - ===3.3.3 Current shunt sensor ===120 +[[image:1732202402284-903.png]] 126 126 127 - To configure the shunt currentsensorparameters,selectthe menu"Signals→ Currentshunt sensor":122 +If the required sensor type is not listed, the “Nominal current” and “Sensitivity” parameters must be manually entered. 128 128 129 -[[Shunt sensor settings>>image:1732202640889-562.png||data-xwiki-image-style-alignment="center" height="342" width="265"]] 130 - 131 -In this section: 132 - 133 -* Settings: 134 -* Enable – a flag to start interaction with BMS Current Sensor (if interaction is enabled then BMS doesn’t use Hall-Effect current sensor which settings are described in the menu "Signals → Current sensor"); 135 -* Node ID – an address of BMS Current Sensor in CANopen network; 136 -* Dispatch timeout – timeout of dispatching packages from BMS Current Sensor (if no data is being received from current sensor during this time, the “Shunt offline” flag is set), millisecond; 137 -* Zero level threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is lower than T,,0,,, BMS will assume that current flowing through the battery is zero); 138 -* Mean level threshold – TM level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is between T,,M,, and T,,0,,, BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, BMS will use instantaneous value of current I,,I,,); 139 -* Invert – a flag to invert current values; 140 -* Sensor state: 141 -** Online – a flag showing that the communication with the BMS Current Sensor is established; 142 -** Errors – a list of internal errors of the shunt sensor; 143 -** Current – an instantaneous value of current measured by the BMS Current Sensor, A (measuring frequency is 50 Hz); 144 -** Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); 145 -** Temperature – a temperature of the shunt sensor, °C. 146 - 147 -=== 3.3.4 Temperature sensor === 148 - 149 -To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor": 124 +Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a zero level signal.
- 1732202427741-614.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.1 KB - Content
- 1732202640889-562.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.7 KB - Content