Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -116,8 +116,47 @@ 116 116 117 117 (% class="box infomessage" %) 118 118 ((( 119 -If the "Sensor type is selected, the “Nominal current” and “Sensitivity” fields are automatically filled. 120 -If the required sensor typeis notlisted, the “Nominal current” and “Sensitivity” parameters must be manually entered.119 +If the "Sensor type" is selected, the “Nominal current” and “Sensitivity” fields are automatically filled. 120 +If the "Sensor type" has no necessary preset, the “Nominal current” and “Sensitivity” parameters must be **manually **entered. 121 121 ))) 122 122 123 -Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a zero level signal. 123 +Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a reference line (zero level signal). 124 + 125 +=== 3.3.3 Current shunt sensor === 126 + 127 +To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor": 128 + 129 +[[Shunt sensor settings>>image:1732202640889-562.png||data-xwiki-image-style-alignment="center" height="342" width="265"]] 130 + 131 +In this section: 132 + 133 +* Settings: 134 +* Enable – a flag to start interaction with BMS Current Sensor (if interaction is enabled then BMS doesn’t use Hall-Effect current sensor which settings are described in the menu "Signals → Current sensor"); 135 +* Node ID – an address of BMS Current Sensor in CANopen network; 136 +* Dispatch timeout – timeout of dispatching packages from BMS Current Sensor (if no data is being received from current sensor during this time, the “Shunt offline” flag is set), millisecond; 137 +* Zero level threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is lower than T,,0,,, BMS will assume that current flowing through the battery is zero); 138 +* Mean level threshold – TM level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is between T,,M,, and T,,0,,, BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, BMS will use instantaneous value of current I,,I,,); 139 +* Invert – a flag to invert current values; 140 +* Sensor state: 141 +** Online – a flag showing that the communication with the BMS Current Sensor is established; 142 +** Errors – a list of internal errors of the shunt sensor; 143 +** Current – an instantaneous value of current measured by the BMS Current Sensor, A (measuring frequency is 50 Hz); 144 +** Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); 145 +** Temperature – a temperature of the shunt sensor, °C. 146 + 147 +=== 3.3.4 Temperature sensor === 148 + 149 +To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor": 150 + 151 +[[Temperature sensors settings>>image:1732204766138-628.png||data-xwiki-image-style-alignment="center" height="112" width="256"]] 152 + 153 + 154 +In this section: 155 + 156 +* Type – type of temperature sensors. 157 +* Mask - 158 + 159 +(% class="box infomessage" %) 160 +((( 161 +**Note:** Temperature sensors connected to the BMS Main 2.x and BMS Logic boards must be the same type. 162 +)))
- 1732202640889-562.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.7 KB - Content
- 1732204766138-628.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.9 KB - Content