37 37  BMS Main 2.x board has 4 analog inputs for connecting current, temperature and humidity sensors. **Assignment of analog inputs must be selected as follows**:
38 38  
39 39  * Analog Input #1– Current sensor;
40 -* Analog Input #2– No input / Current sensor re (see note);
40 +* Analog Input #2– No input / Current zero level (see note);
41 41  * Analog Input #3 – No input / Temperature sensor / Current sensor (AUX) / Current zero level (AUX);
42 42  * Analog Input #4 – No input / Humidity sensor / Current sensor (AUX) / Current zero level (AUX).
43 43  
... ... @@ -53,7 +53,7 @@
53 53  
54 54  (% class="box infomessage" %)
55 55  (((
56 -**Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current sensor reference line" assignment.
56 +**Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current zero level" assignment.
57 57  )))
58 58  
59 59   To configure the input discrete and analog signals, select the menu "Signals → Input signals":
... ... @@ -60,8 +60,9 @@
60 60  
61 61  [[Input signals section>>image:1732201986070-992.png||data-xwiki-image-style-alignment="center" height="290" width="272"]]
62 62  
63 - The order of the numbering of the discrete and analog inputs corresponds to the order of the numbering on the board.
64 64  
64 +The order of the numbering of the discrete and analog inputs corresponds to the order of the numbering on the board.
65 +
65 65  In this section:
66 66  
67 67  * Discrete inputs:
... ... @@ -89,8 +89,6 @@
89 89  ** Current sensor (AUX) – additional current sensor for measuring current in a series of cells;
90 90  ** Current zero level (AUX) – zero level bus for additional current sensor.
91 91  
92 -=== 3.3.2 Current sensor ===
93 +3.3.2
93 93  
94 94  After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board.
95 -
96 -To configure the current sensor parameters, select the menu "Signals → Current sensor":