Last modified by Admin on 2026/06/29 16:25

From version 31.1
edited by Admin
on 2026/06/29 16:23
Change comment: There is no comment for this version
To version 30.18
edited by Admin
on 2026/06/29 16:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -41,14 +41,12 @@
41 41  **Analog inputs** in this section:
42 42  
43 43  * No input;
44 -* Current sensor signal – main current sensor output;
45 -* Current sensor reference line – main current sensor zero level;
44 +* Current sensor signal;
45 +* Current sensor reference line;
46 46  * Temperature sensor;
47 47  * Humidity sensor;
48 -* Current sensor signal (AUX) – additional (AUX) current sensor output;
49 -* Current sensor reference line (AUX) – additional (AUX) current sensor zero level;
50 -* Current sensor signal (2nd range) – second range output of main dual range sensor (used in "Dual range sensor" and "Separate dual range sensors" modes);
51 -* Current sensor signal (2nd range, AUX) – second range of additional (AUX) dual range sensor (used in "Separate dual range sensors" mode);
48 +* Current sensor signal (AUX) – additional current sensor for measuring current in a series of cells;
49 +* Current zero level (AUX) – zero level bus for additional current sensor.
52 52  
53 53  (% class="box warningmessage" %)
54 54  (((
... ... @@ -66,17 +66,16 @@
66 66  In the «Primary sensor» и «Auxiliary sensor» sections:
67 67  
68 68  * Sensor type – drop-down menu with presets for most popular sensor types;
69 -* Mode – main and additional (AUX) sensors mode:
70 -** Disabled – additional (AUX)sensor is not used:
71 -** Parallel sensors – additional (AUX) sensor is located in parallel circuit. Final current is estimated as sum of both sensors values;
72 -** Serial sensors – additional (AUX) sensor is located on the same circuit. Final current is estimated as average of both sensors values;
73 -** Separated sensors – additional (AUX) sensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]);
74 -** Dual range sensor – main sensor is a dual range sensor. Transition to a second range measurements is done by a "Current threshold" parameter;
75 -** Separate dual range sensors – main and additional sensors are dual range sensors, located on the same line. Since this mode requires all analog inputs, the modification of BMS Main board is required;
67 +* Mode – auxiliary sensor mode:
68 +** Disabled – auxiliary sensor is not used:
69 +** Parallel sensors – auxiliary sensor is located in parallel circuit. Final current is estimated as sum of both sensors values;
70 +** Serial sensors – auxiliary sensor is located on the same circuit. Final current is estimated as average of both sensors values;
71 +** Separated sensors – auxiliary sensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]);
72 +** Dual range sensor – auxiliary sensor line i used to measure the second coil of dual range sensor;
73 +** Separate dual range sensors – auxiliary sensor and main sensor are dual range sensors, located on the same line (P13 header modification is required!);
76 76  * Nominal current – rated current of the sensor according to the datasheet, А;
77 77  * Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nominal.,,;
78 -* Current threshold – a value below which current is measured by low-current range of dual range sensor, A;
79 -* Voltage, corresponding 0A – calibrated zero level of the current sensor, V;
76 +* Zero level – level "0A" of the current sensor, V;
80 80  * Multiply the charging current (experimental) – experimental flag for scaling the charging current by given multiplier;
81 81  * Multiplier – charging current multiplier;
82 82