Changes for page 3.3 Input and output signals
Last modified by Admin on 2026/04/24 10:30
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Battery management systems. EOL devices.BMS Main 2\.1.3\. Configuration.WebHome1 +Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -57,7 +57,7 @@ 57 57 58 58 (% class="box warningmessage" %) 59 59 ((( 60 -**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc:Battery management systems. EOL devices.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).60 +**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 61 61 ))) 62 62 63 63 (% class="box warningmessage" %) ... ... @@ -83,11 +83,11 @@ 83 83 * Sensor type – drop-down menu with presets for most popular sensor types; 84 84 * Mode – auxiliary sensor mode: 85 85 ** Disabled – auxiliary sensor is not used: 86 -** Parallel sensors – auxiliary sensor is located in parallel circuit. Finalcurrentisestimatedassumofboth sensors values;87 -** Serial sensors – auxiliarysensorislocatedonthesame circuit.Finalcurrentisestimatedasaverageofbothsensors values;88 -** Separated sensors – auxiliarysensorisusedtomeasurethecurrentinsecondseries of cells(см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]);89 -** Dual range sensor – auxiliarysensorlineiusedtomeasurethesecondcoilof dual range sensor;90 -** Separate dual range sensors – auxiliarysensorandmainsensor are dual range sensors,locatedonthesame line (P13 header modification is required!);86 +** Parallel sensors – auxiliary sensor is located in parallel circuit. Итоговое значение будет равно сумме показаний двух датчиков; 87 +** Serial sensors – режим датчика тока из той же цепи. Итоговое значение будет равно среднему арифметическому показаний двух датчиков; 88 +** Separated sensors – дополнительный датчик используется для измерений потребления второй последовательной серии ячеек (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]); 89 +** Dual range sensor – вход дополнительного датчика используется для измерения второй катушки двудиапазонного датчика тока; 90 +** Separate dual range sensors – использование двух двухдиапазонных датчиков тока, подключенных в одну цепь; 91 91 * Nominal current – rated current of the sensor according to the datasheet, А; 92 92 * Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nominal.,,; 93 93 * Zero level – level "0A" of the current sensor, V; ... ... @@ -208,9 +208,9 @@ 208 208 209 209 If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[Discharging control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargingcontrol"]]). 210 210 211 -If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc:Battery management systems. EOL devices.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).211 +If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 212 212 213 -If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc:Battery management systems. EOL devices.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).213 +If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 214 214 215 215 If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[Discharging (AUX) control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischarging(AUX)control"]]). 216 216