Changes for page 3.3 Input and output signals
Last modified by Admin on 2026/06/29 16:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -41,14 +41,12 @@ 41 41 **Analog inputs** in this section: 42 42 43 43 * No input; 44 -* Current sensor signal – main current sensor output;45 -* Current sensor reference line – main current sensor zero level;44 +* Current sensor signal; 45 +* Current sensor reference line; 46 46 * Temperature sensor; 47 47 * Humidity sensor; 48 -* Current sensor signal (AUX) – additional (AUX) current sensor output; 49 -* Current sensor reference line (AUX) – additional (AUX) current sensor zero level; 50 -* Current sensor signal (2nd range) – second range output of main dual range sensor (used in "Dual range sensor" and "Separate dual range sensors" modes); 51 -* Current sensor signal (2nd range, AUX) – second range of additional (AUX) dual range sensor (used in "Separate dual range sensors" mode); 48 +* Current sensor signal (AUX) – additional current sensor for measuring current in a series of cells; 49 +* Current zero level (AUX) – zero level bus for additional current sensor. 52 52 53 53 (% class="box warningmessage" %) 54 54 ((( ... ... @@ -66,16 +66,15 @@ 66 66 In the «Primary sensor» и «Auxiliary sensor» sections: 67 67 68 68 * Sensor type – drop-down menu with presets for most popular sensor types; 69 -* Mode – main and additional(AUX)sensorsmode:70 -** Disabled – a dditional(AUX)sensor is not used:71 -** Parallel sensors – a dditional(AUX)sensor is located in parallel circuit. Final current is estimated as sum of both sensors values;72 -** Serial sensors – a dditional(AUX)sensor is located on the same circuit. Final current is estimated as average of both sensors values;73 -** Separated sensors – a dditional(AUX)sensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]);74 -** Dual range sensor – main sensorisadualrangesensor.Transitiontoasecondrangemeasurementsisdonebya"Currentthreshold" parameter;75 -** Separate dual range sensors – main and additionalsensorsare dual range sensors, located on the same line.Sincethis moderequiresall analog inputs, themodificationof BMS Main board is required;67 +* Mode – auxiliary sensor mode: 68 +** Disabled – auxiliary sensor is not used: 69 +** Parallel sensors – auxiliary sensor is located in parallel circuit. Final current is estimated as sum of both sensors values; 70 +** Serial sensors – auxiliary sensor is located on the same circuit. Final current is estimated as average of both sensors values; 71 +** Separated sensors – auxiliary sensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]); 72 +** Dual range sensor – auxiliary sensor line i used to measure the second coil of dual range sensor; 73 +** Separate dual range sensors – auxiliary sensor and main sensor are dual range sensors, located on the same line (P13 header modification is required!); 76 76 * Nominal current – rated current of the sensor according to the datasheet, А; 77 77 * Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nominal.,,; 78 -* Current threshold 79 79 * Zero level – level "0A" of the current sensor, V; 80 80 * Multiply the charging current (experimental) – experimental flag for scaling the charging current by given multiplier; 81 81 * Multiplier – charging current multiplier;