Changes for page 3.3 Input and output signals
Last modified by Admin on 2026/06/29 16:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -47,7 +47,8 @@ 47 47 * Humidity sensor; 48 48 * Current sensor signal (AUX) – additional (AUX) current sensor output; 49 49 * Current sensor reference line (AUX) – additional (AUX) current sensor zero level; 50 -* Current sensor signal (2nd range) – second 50 +* Current sensor signal (2nd range) – second range output of main dual range sensor (used in "Dual range sensor" and "Separate dual range sensors" modes); 51 +* Current sensor signal (2nd range, AUX) – second range of additional (AUX) dual range sensor (used in "Separate dual range sensors" mode); 51 51 52 52 (% class="box warningmessage" %) 53 53 ((( ... ... @@ -65,13 +65,13 @@ 65 65 In the «Primary sensor» и «Auxiliary sensor» sections: 66 66 67 67 * Sensor type – drop-down menu with presets for most popular sensor types; 68 -* Mode – a uxiliarysensor mode:69 -** Disabled – a uxiliarysensor is not used:70 -** Parallel sensors – a uxiliarysensor is located in parallel circuit. Final current is estimated as sum of both sensors values;71 -** Serial sensors – a uxiliarysensor is located on the same circuit. Final current is estimated as average of both sensors values;72 -** Separated sensors – a uxiliarysensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]);73 -** Dual range sensor – a uxiliarysensorlineiusedtomeasurethesecondcoilofdualrangesensor;74 -** Separate dual range sensors – a uxiliarysensorand main sensor are dual range sensors, located on the same line (P13 header modification is required!);69 +* Mode – main and additional (AUX) sensors mode: 70 +** Disabled – additional (AUX)sensor is not used: 71 +** Parallel sensors – additional (AUX) sensor is located in parallel circuit. Final current is estimated as sum of both sensors values; 72 +** Serial sensors – additional (AUX) sensor is located on the same circuit. Final current is estimated as average of both sensors values; 73 +** Separated sensors – additional (AUX) sensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]); 74 +** Dual range sensor – main sensor is a dual range sensor. Transition to a second range measurements is done by a "Current threshold" parameter; 75 +** Separate dual range sensors – main and additional sensorsand main sensor are dual range sensors, located on the same line (P13 header modification is required!); 75 75 * Nominal current – rated current of the sensor according to the datasheet, А; 76 76 * Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nominal.,,; 77 77 * Zero level – level "0A" of the current sensor, V;