... ... @@ -46,7 +46,9 @@
46 46  * Temperature sensor;
47 47  * Humidity sensor;
48 48  * Current sensor signal (AUX) – additional (AUX) current sensor output;
49 -* Current sensor reference line (AUX) – additional (AUX) current sensor zero level.
49 +* Current sensor reference line (AUX) – additional (AUX) current sensor zero level;
50 +* Current sensor signal (2nd range) – second range output of main dual range sensor (used in "Dual range sensor" and "Separate dual range sensors" modes);
51 +* Current sensor signal (2nd range, AUX) – second range of additional (AUX) dual range sensor (used in "Separate dual range sensors" mode);
50 50  
51 51  (% class="box warningmessage" %)
52 52  (((
... ... @@ -64,8 +64,8 @@
64 64  In the «Primary sensor» и «Auxiliary sensor» sections:
65 65  
66 66  * Sensor type – drop-down menu with presets for most popular sensor types;
67 -* Mode – auxiliary sensor mode:
68 -** Disabled – auxiliary sensor is not used:
69 +* Mode – main and additional (AUX) sensors mode:
70 +** Disabled – additional (AUX)sensor is not used:
69 69  ** Parallel sensors – auxiliary sensor is located in parallel circuit. Final current is estimated as sum of both sensors values;
70 70  ** Serial sensors – auxiliary sensor is located on the same circuit. Final current is estimated as average of both sensors values;
71 71  ** Separated sensors – auxiliary sensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]);