Changes for page 3.3 Input and output signals
Last modified by Admin on 2026/06/29 16:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -41,12 +41,14 @@ 41 41 **Analog inputs** in this section: 42 42 43 43 * No input; 44 -* Current sensor signal; 45 -* Current sensor reference line; 44 +* Current sensor signal – main current sensor output; 45 +* Current sensor reference line – main current sensor zero level; 46 46 * Temperature sensor; 47 47 * Humidity sensor; 48 -* Current sensor signal (AUX) – additional current sensor for measuring current in a series of cells; 49 -* Current zero level (AUX) – zero level bus for additional current sensor. 48 +* Current sensor signal (AUX) – additional (AUX) current sensor output; 49 +* Current sensor reference line (AUX) – additional (AUX) current sensor zero level; 50 +* Current sensor signal (2nd range) – second range output of main dual range sensor (used in "Dual range sensor" and "Separate dual range sensors" modes); 51 +* Current sensor signal (2nd range, AUX) – second range of additional (AUX) dual range sensor (used in "Separate dual range sensors" mode); 50 50 51 51 (% class="box warningmessage" %) 52 52 ((( ... ... @@ -64,16 +64,17 @@ 64 64 In the «Primary sensor» и «Auxiliary sensor» sections: 65 65 66 66 * Sensor type – drop-down menu with presets for most popular sensor types; 67 -* Mode – a uxiliarysensor mode:68 -** Disabled – a uxiliarysensor is not used:69 -** Parallel sensors – a uxiliarysensor is located in parallel circuit. Final current is estimated as sum of both sensors values;70 -** Serial sensors – a uxiliarysensor is located on the same circuit. Final current is estimated as average of both sensors values;71 -** Separated sensors – a uxiliarysensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]);72 -** Dual range sensor – a uxiliarysensorlineiusedtomeasurethesecondcoilofdualrangesensor;73 -** Separate dual range sensors – a uxiliary sensorandmain sensor are dual range sensors, located on the same line(P13header modification is required!);69 +* Mode – main and additional (AUX) sensors mode: 70 +** Disabled – additional (AUX)sensor is not used: 71 +** Parallel sensors – additional (AUX) sensor is located in parallel circuit. Final current is estimated as sum of both sensors values; 72 +** Serial sensors – additional (AUX) sensor is located on the same circuit. Final current is estimated as average of both sensors values; 73 +** Separated sensors – additional (AUX) sensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]); 74 +** Dual range sensor – main sensor is a dual range sensor. Transition to a second range measurements is done by a "Current threshold" parameter; 75 +** Separate dual range sensors – main and additional sensors are dual range sensors, located on the same line. Since this mode requires all analog inputs, the modification of BMS Main board is required; 74 74 * Nominal current – rated current of the sensor according to the datasheet, А; 75 75 * Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nominal.,,; 76 -* Zero level – level "0A" of the current sensor, V; 78 +* Current threshold – a value below which current is measured by low-current range of dual range sensor, A; 79 +* Voltage, corresponding 0A – calibrated zero level of the current sensor output, V; 77 77 * Multiply the charging current (experimental) – experimental flag for scaling the charging current by given multiplier; 78 78 * Multiplier – charging current multiplier; 79 79