... ... @@ -57,3 +57,39 @@
57 57  )))
58 58  
59 59   To configure the input discrete and analog signals, select the menu "Signals → Input signals":
60 +
61 +[[Input signals section>>image:1732201986070-992.png||data-xwiki-image-style-alignment="center" height="290" width="272"]]
62 +
63 +
64 +The order of the numbering of the discrete and analog inputs corresponds to the order of the numbering on the board.
65 +
66 +In this section:
67 +
68 +* Discrete inputs:
69 +** No input;
70 +** Battery cover – a signal from the battery cover trailer;
71 +** Charger connected – a signal from the charger connector;
72 +** Power up/down request – a signal from the external power monitor which is used for proper powering BMS up or down;
73 +** Inhibit charging – a command to open the charging relay;
74 +** Inhibit discharging – a command to open the discharging relay;
75 +** CH contactor feedback – a feedback signal from the charging contactor;
76 +** DCH contactor feedback – a feedback signal from the discharging contactor;
77 +** Insulation status – a signal from an external insulation monitoring device;
78 +** Charge request – a request for closing the charging contactor;
79 +** Precharge request – a request for closing the precharging contactor;
80 +** Discharge request – a request for closing the discharging contactor;
81 +** PCH contactor feedback – a feedback signal from the precharging contactor;
82 +** CH/DCH contactor feedback – a feedback signal from the charging/discharging contactor;
83 +** Main contactor feedback – a feedback signal from the main contactor.
84 +* Analog inputs:
85 +** No input;
86 +** Current sensor;
87 +** Current zero level;
88 +** Temperature sensor;
89 +** Humidity sensor;
90 +** Current sensor (AUX) – additional current sensor for measuring current in a series of cells;
91 +** Current zero level (AUX) – zero level bus for additional current sensor.
92 +
93 +3.3.2
94 +
95 +After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board.
1732201986070-992.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +24.0 KB
Content