Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,15 +18,15 @@ 18 18 * CH/DCH contactor feedback; 19 19 * Main contactor feedback. 20 20 21 -If the " signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see section Battery cover protection).21 +If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see section Battery cover protection). 22 22 23 -if the " charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see sections Charge control and Discharge control).23 +if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see sections Charge control and Discharge control). 24 24 25 -If the " power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see sections Charge control and Discharge control).25 +If the "Power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see sections Charge control and Discharge control). 26 26 27 -If the “ inhibit charging” assignment is selected, the discrete input is used to open the charging relay.27 +If the “Inhibit charging” assignment is selected, the discrete input is used to open the charging relay. 28 28 29 -If the “ inhibit discharging” assignment is selected, the discrete input is used to open the discharging relay.29 +If the “Inhibit discharging” assignment is selected, the discrete input is used to open the discharging relay. 30 30 31 31 If the “CH contactor feedback”, “DCH contactor feedback”, “PCH contactor feedback”, “CH/DCH contactor feedback” or “Main contactor feedback” assignment is selected, the discrete input is involved in monitoring the corresponding contactor’s feedback signal (see section Contactor feedback check). 32 32 ... ... @@ -48,7 +48,12 @@ 48 48 49 49 (% class="box warningmessage" %) 50 50 ((( 51 -** Reassignment of analog inputs is unacceptable.**51 +**Warning: **reassignment of analog inputs is **unacceptable.** 52 52 ))) 53 53 54 -Note – The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current zero level" assignment. 54 +(% class="box infomessage" %) 55 +((( 56 +**Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current zero level" assignment. 57 +))) 58 + 59 + To configure the input discrete and analog signals, select the menu "Signals → Input signals":