Changes for page 3.3 Input and output signals
Last modified by Admin on 2026/04/24 10:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,10 +16,7 @@ 16 16 17 17 [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]] 18 18 19 -(% class="box infomessage" %) 20 -((( 21 21 A list of available **discrete input assignments **is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 22 -))) 23 23 24 24 If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[Battery cover protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]). 25 25 ... ... @@ -80,14 +80,7 @@ 80 80 81 81 In the «Primary sensor» и «Auxiliary sensor» sections: 82 82 83 -* Sensor type – drop-down menu with presets for most popular sensor types; 84 -* Mode – auxiliary sensor mode: 85 -** Disabled – auxiliary sensor is not used: 86 -** Parallel sensors – auxiliary sensor is located in parallel circuit. Final current is estimated as sum of both sensors values; 87 -** Serial sensors – auxiliary sensor is located on the same circuit. Final current is estimated as average of both sensors values; 88 -** Separated sensors – auxiliary sensor is used to measu(см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]); 89 -** Dual range sensor – вход дополнительного датчика используется для измерения второй катушки двудиапазонного датчика тока; 90 -** Separate dual range sensors – использование двух двухдиапазонных датчиков тока, подключенных в одну цепь; 80 +* Sensor type – drop-down menu with supported sensor types; 91 91 * Nominal current – rated current of the sensor according to the datasheet, А; 92 92 * Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nominal.,,; 93 93 * Zero level – level "0A" of the current sensor, V; ... ... @@ -169,10 +169,7 @@ 169 169 170 170 [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]] 171 171 172 -(% class="box infomessage" %) 173 -((( 174 174 A list of available **discrete output assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 175 -))) 176 176 177 177 If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[Low SOC signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]). 178 178 ... ... @@ -191,10 +191,7 @@ 191 191 If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[Power down control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HPowerdowncontrol"]]). 192 192 193 193 194 -(% class="box infomessage" %) 195 -((( 196 196 A list of available **relay assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 197 -))) 198 198 199 199 If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charging control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargingcontrol"]]). 200 200