Last modified by Admin on 2026/04/24 10:30

From version 29.1
edited by Admin
on 2025/04/09 12:34
Change comment: There is no comment for this version
To version 30.11
edited by Admin
on 2026/04/24 10:29
Change comment: Renamed back-links.

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome
1 +Battery management systems.BMS Main 2\.1 (End-of-Life).3\. Configuration.WebHome
Content
... ... @@ -57,7 +57,7 @@
57 57  
58 58  (% class="box warningmessage" %)
59 59  (((
60 -**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).
60 +**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1 (End-of-Life).3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).
61 61  )))
62 62  
63 63  (% class="box warningmessage" %)
... ... @@ -80,7 +80,14 @@
80 80  
81 81  In the «Primary sensor» и «Auxiliary sensor» sections:
82 82  
83 -* Sensor type – drop-down menu with supported sensor types;
83 +* Sensor type – drop-down menu with presets for most popular sensor types;
84 +* Mode – auxiliary sensor mode:
85 +** Disabled – auxiliary sensor is not used:
86 +** Parallel sensors – auxiliary sensor is located in parallel circuit. Final current is estimated as sum of both sensors values;
87 +** Serial sensors – auxiliary sensor is located on the same circuit. Final current is estimated as average of both sensors values;
88 +** Separated sensors – auxiliary sensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]);
89 +** Dual range sensor – auxiliary sensor line i used to measure the second coil of dual range sensor;
90 +** Separate dual range sensors – auxiliary sensor and main sensor are dual range sensors, located on the same line (P13 header modification is required!);
84 84  * Nominal current – rated current of the sensor according to the datasheet, А;
85 85  * Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nominal.,,;
86 86  * Zero level – level "0A" of the current sensor, V;
... ... @@ -201,9 +201,9 @@
201 201  
202 202  If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[Discharging control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargingcontrol"]]).
203 203  
204 -If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).
211 +If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1 (End-of-Life).3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).
205 205  
206 -If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).
213 +If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1 (End-of-Life).3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).
207 207  
208 208  If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[Discharging (AUX) control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischarging(AUX)control"]]).
209 209