Changes for page 3.3 Input and output signals
Last modified by Admin on 2026/06/29 16:25
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,7 +16,10 @@ 16 16 17 17 [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]] 18 18 19 +(% class="box infomessage" %) 20 +((( 19 19 A list of available **discrete input assignments **is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 22 +))) 20 20 21 21 If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[Battery cover protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]). 22 22 ... ... @@ -38,35 +38,18 @@ 38 38 **Analog inputs** in this section: 39 39 40 40 * No input; 41 -* Current sensor; 42 -* Current zerolevel;44 +* Current sensor signal; 45 +* Current sensor reference line; 43 43 * Temperature sensor; 44 44 * Humidity sensor; 45 -* Current sensor (AUX) – additional current sensor for measuring current in a series of cells; 48 +* Current sensor signal (AUX) – additional current sensor for measuring current in a series of cells; 46 46 * Current zero level (AUX) – zero level bus for additional current sensor. 47 47 48 -**Assignment of analog inputs must be selected as follows**: 49 - 50 -* Analog Input #1 – Current sensor; 51 -* Analog Input #2 – No input / Current sensor reference line / Current sensor (2nd range) (see note); 52 -* Analog Input #3 – No input / Temperature sensor / Current sensor (AUX); 53 -* Analog Input #4 – No input / Humidity sensor / Current reference line (AUX) / Current sensor (2nd range) (AUX). 54 - 55 55 (% class="box warningmessage" %) 56 56 ((( 57 -**Important**: the connection of anadditionalcurrentsensor(AUX)is possiblefor specialhardwarerevision of the BMS Main 2.x board. Using an additionalcurrentsensoris possible inthe configurationwhenBMS Mainserves two galvanically isolated cell series (see [[Series balancing>>doc:Battery management systems.BMS Main2\.1.3\.Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).53 +**Important**: the using of analog input #4 is possible hardware modification of the BMS Main 2.x board. 58 58 ))) 59 59 60 -(% class="box warningmessage" %) 61 -((( 62 -**Warning: **reassignment of analog inputs is **unacceptable.** 63 -))) 64 - 65 -(% class="box infomessage" %) 66 -((( 67 -**Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current sensor reference line" assignment. 68 -))) 69 - 70 70 === Current sensor === 71 71 72 72 After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board. ... ... @@ -77,7 +77,14 @@ 77 77 78 78 In the «Primary sensor» и «Auxiliary sensor» sections: 79 79 80 -* Sensor type – drop-down menu with supported sensor types; 66 +* Sensor type – drop-down menu with presets for most popular sensor types; 67 +* Mode – auxiliary sensor mode: 68 +** Disabled – auxiliary sensor is not used: 69 +** Parallel sensors – auxiliary sensor is located in parallel circuit. Final current is estimated as sum of both sensors values; 70 +** Serial sensors – auxiliary sensor is located on the same circuit. Final current is estimated as average of both sensors values; 71 +** Separated sensors – auxiliary sensor is used to measure the current in second series of cells (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]); 72 +** Dual range sensor – auxiliary sensor line i used to measure the second coil of dual range sensor; 73 +** Separate dual range sensors – auxiliary sensor and main sensor are dual range sensors, located on the same line (P13 header modification is required!); 81 81 * Nominal current – rated current of the sensor according to the datasheet, А; 82 82 * Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nominal.,,; 83 83 * Zero level – level "0A" of the current sensor, V; ... ... @@ -159,7 +159,10 @@ 159 159 160 160 [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]] 161 161 155 +(% class="box infomessage" %) 156 +((( 162 162 A list of available **discrete output assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 158 +))) 163 163 164 164 If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[Low SOC signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]). 165 165 ... ... @@ -178,7 +178,10 @@ 178 178 If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[Power down control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HPowerdowncontrol"]]). 179 179 180 180 177 +(% class="box infomessage" %) 178 +((( 181 181 A list of available **relay assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 180 +))) 182 182 183 183 If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charging control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargingcontrol"]]). 184 184