Changes for page 3.3 Input and output signals
Last modified by Admin on 2026/04/24 10:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,7 +16,10 @@ 16 16 17 17 [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]] 18 18 19 +(% class="box infomessage" %) 20 +((( 19 19 A list of available **discrete input assignments **is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 22 +))) 20 20 21 21 If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[Battery cover protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]). 22 22 ... ... @@ -77,7 +77,14 @@ 77 77 78 78 In the «Primary sensor» и «Auxiliary sensor» sections: 79 79 80 -* Sensor type – drop-down menu with supported sensor types; 83 +* Sensor type – drop-down menu with presets for most popular sensor types; 84 +* Mode – auxiliary sensor mode: 85 +** Disabled – auxiliary sensor is not used: 86 +** Parallel sensors – auxiliary sensor is located in parallel circuit. Итоговое значение будет равно сумме показаний двух датчиков; 87 +** Serial sensors – режим датчика тока из той же цепи. Итоговое значение будет равно среднему арифметическому показаний двух датчиков; 88 +** Separated sensors – дополнительный датчик используется для измерений потребления второй последовательной серии ячеек (см. [[Series balancing>>url:https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202.1/3.%20Configuration/3.4%20Battery%20parameters/?HSeriesbalancing#HSeriesbalancing]]); 89 +** Dual range sensor – вход дополнительного датчика используется для измерения второй катушки двудиапазонного датчика тока; 90 +** Separate dual range sensors – использование двух двухдиапазонных датчиков тока, подключенных в одну цепь; 81 81 * Nominal current – rated current of the sensor according to the datasheet, А; 82 82 * Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nominal.,,; 83 83 * Zero level – level "0A" of the current sensor, V; ... ... @@ -159,7 +159,10 @@ 159 159 160 160 [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]] 161 161 172 +(% class="box infomessage" %) 173 +((( 162 162 A list of available **discrete output assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 175 +))) 163 163 164 164 If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[Low SOC signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]). 165 165 ... ... @@ -178,11 +178,14 @@ 178 178 If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[Power down control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HPowerdowncontrol"]]). 179 179 180 180 194 +(% class="box infomessage" %) 195 +((( 181 181 A list of available **relay assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 197 +))) 182 182 183 -If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charg econtrol>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]).199 +If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charging control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargingcontrol"]]). 184 184 185 -If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[Discharg econtrol>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).201 +If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[Discharging control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargingcontrol"]]). 186 186 187 187 If the "Allow charging" assignment is selected, the relay is used to give the charger an allowance to charge the battery (see [[Charging control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargingcontrol"]]). 188 188