... ... @@ -16,24 +16,8 @@
16 16  
17 17  [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]]
18 18  
19 -**Discrete inputs** in this section:
19 +A list of available **discrete input assignments **is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
20 20  
21 -* No input;
22 -* Battery cover – a signal from the battery cover trailer;
23 -* Charger connected – a signal from the charger connector;
24 -* Power up/down request – a signal from the external power monitor which is used for proper powering BMS up or down;
25 -* Inhibit charging – a command to open the charging relay;
26 -* Inhibit discharging – a command to open the discharging relay;
27 -* CH contactor feedback – a feedback signal from the charging contactor;
28 -* DCH contactor feedback – a feedback signal from the discharging contactor;
29 -* Insulation status – a signal from an external insulation monitoring device;
30 -* Charge request – a request for closing the charging contactor;
31 -* Precharge request – a request for closing the precharging contactor;
32 -* Discharge request – a request for closing the discharging contactor;
33 -* PCH contactor feedback – a feedback signal from the precharging contactor;
34 -* CH/DCH contactor feedback – a feedback signal from the charging/discharging contactor;
35 -* Main contactor feedback – a feedback signal from the main contactor.
36 -
37 37  If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[Battery cover protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]).
38 38  
39 39  if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).
... ... @@ -175,18 +175,8 @@
175 175  
176 176  [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]]
177 177  
178 -**Discrete outputs** in this section:
162 +A list of available **discrete output assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
179 179  
180 -* No output;
181 -* Low SOC;
182 -* High charging current;
183 -* Cooler;
184 -* Heater;
185 -* Allow charging;
186 -* Precharging;
187 -* Acknowledgement of power down;
188 -* Power up;
189 -
190 190  If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[Low SOC signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]).
191 191  
192 192  If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see [[High charging current signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHighchargingcurrentsignal"]]).
... ... @@ -204,21 +204,8 @@
204 204  If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[Power down control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HPowerdowncontrol"]]).
205 205  
206 206  
207 -**Relay assignments** in this section:
181 +A list of available **relay assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
208 208  
209 -* No relay;
210 -* Charging;
211 -* Discharging;
212 -* Allow charging;
213 -* Cooler;
214 -* Heater;
215 -* Precharging;
216 -* Balancing series 1;
217 -* Balancing series 2;
218 -* Discharging (AUX);
219 -* Main contactor;
220 -* Power up.
221 -
222 222  If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]).
223 223  
224 224  If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).