Last modified by Admin on 2025/04/09 12:34

From version 26.1
edited by Admin
on 2025/01/09 21:40
Change comment: There is no comment for this version
To version 26.2
edited by Admin
on 2025/02/19 10:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -16,24 +16,8 @@
16 16  
17 17  [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]]
18 18  
19 -**Discrete inputs** in this section:
19 +A list of available **discrete input assignments **is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
20 20  
21 -* No input;
22 -* Battery cover – a signal from the battery cover trailer;
23 -* Charger connected – a signal from the charger connector;
24 -* Power up/down request – a signal from the external power monitor which is used for proper powering BMS up or down;
25 -* Inhibit charging – a command to open the charging relay;
26 -* Inhibit discharging – a command to open the discharging relay;
27 -* CH contactor feedback – a feedback signal from the charging contactor;
28 -* DCH contactor feedback – a feedback signal from the discharging contactor;
29 -* Insulation status – a signal from an external insulation monitoring device;
30 -* Charge request – a request for closing the charging contactor;
31 -* Precharge request – a request for closing the precharging contactor;
32 -* Discharge request – a request for closing the discharging contactor;
33 -* PCH contactor feedback – a feedback signal from the precharging contactor;
34 -* CH/DCH contactor feedback – a feedback signal from the charging/discharging contactor;
35 -* Main contactor feedback – a feedback signal from the main contactor.
36 -
37 37  If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[Battery cover protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]).
38 38  
39 39  if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).
... ... @@ -175,18 +175,8 @@
175 175  
176 176  [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]]
177 177  
178 -**Discrete outputs** in this section:
162 +A list of available **discrete input assignments **is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
179 179  
180 -* No output;
181 -* Low SOC;
182 -* High charging current;
183 -* Cooler;
184 -* Heater;
185 -* Allow charging;
186 -* Precharging;
187 -* Acknowledgement of power down;
188 -* Power up;
189 -
190 190  If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[Low SOC signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]).
191 191  
192 192  If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see [[High charging current signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHighchargingcurrentsignal"]]).