Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,24 +16,8 @@ 16 16 17 17 [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]] 18 18 19 -** Discrete inputs** inthis section:19 +A list of available **discrete input assignments **is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 20 20 21 -* No input; 22 -* Battery cover – a signal from the battery cover trailer; 23 -* Charger connected – a signal from the charger connector; 24 -* Power up/down request – a signal from the external power monitor which is used for proper powering BMS up or down; 25 -* Inhibit charging – a command to open the charging relay; 26 -* Inhibit discharging – a command to open the discharging relay; 27 -* CH contactor feedback – a feedback signal from the charging contactor; 28 -* DCH contactor feedback – a feedback signal from the discharging contactor; 29 -* Insulation status – a signal from an external insulation monitoring device; 30 -* Charge request – a request for closing the charging contactor; 31 -* Precharge request – a request for closing the precharging contactor; 32 -* Discharge request – a request for closing the discharging contactor; 33 -* PCH contactor feedback – a feedback signal from the precharging contactor; 34 -* CH/DCH contactor feedback – a feedback signal from the charging/discharging contactor; 35 -* Main contactor feedback – a feedback signal from the main contactor. 36 - 37 37 If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[Battery cover protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]). 38 38 39 39 if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). ... ... @@ -146,7 +146,7 @@ 146 146 In this section: 147 147 148 148 * Type – type of temperature sensors; 149 -* Mask – mask to ignore the temperature from the corresponding temperature sensors; bit //i// corresponds to temperature input #(//i//+1) of each BMS Logic device; mask 0x1means that the BMS marks all temperature sensors connected to input #1 of each BMS Logic device as missing and doesn't use them in calculations.133 +* Mask – mask to ignore the temperature from the corresponding temperature sensors; bit //i// corresponds to temperature input //#(i+1)// of each BMS Logic device; mask 0x5 means that the BMS marks all temperature sensors connected to inputs #1 and #3 of each BMS Logic device as missing and doesn't use them in calculations. 150 150 151 151 (% class="box infomessage" %) 152 152 ((( ... ... @@ -175,18 +175,8 @@ 175 175 176 176 [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]] 177 177 178 -** Discrete outputs** inthis section:162 +A list of available **discrete output assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 179 179 180 -* No output; 181 -* Low SOC; 182 -* High charging current; 183 -* Cooler; 184 -* Heater; 185 -* Allow charging; 186 -* Precharging; 187 -* Acknowledgement of power down; 188 -* Power up; 189 - 190 190 If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[Low SOC signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]). 191 191 192 192 If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see [[High charging current signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHighchargingcurrentsignal"]]). ... ... @@ -204,21 +204,8 @@ 204 204 If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[Power down control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HPowerdowncontrol"]]). 205 205 206 206 207 -** Relay assignments** inthis section:181 +A list of available **relay assignments **is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 208 208 209 -* No relay; 210 -* Charging; 211 -* Discharging; 212 -* Allow charging; 213 -* Cooler; 214 -* Heater; 215 -* Precharging; 216 -* Balancing series 1; 217 -* Balancing series 2; 218 -* Discharging (AUX); 219 -* Main contactor; 220 -* Power up. 221 - 222 222 If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 223 223 224 224 If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).