Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main 2\.1.3\. Configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,11 +1,5 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration = 1 +== 3.3.1 Input signals == 3 3 4 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -== Input and output signals == 6 - 7 -=== Input signals === 8 - 9 9 The BMS Main 2.x board has **4 discrete inputs** of the "dry contact" type. For each discrete input, its purpose and the inversion requirement are specified. 10 10 11 11 BMS Main 2.x board has **4 analog inputs** for connecting current, temperature and humidity sensors. ... ... @@ -70,7 +70,7 @@ 70 70 71 71 (% class="box warningmessage" %) 72 72 ((( 73 -**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc: Battery managementystems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).67 +**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 74 74 ))) 75 75 76 76 (% class="box warningmessage" %) ... ... @@ -83,7 +83,7 @@ 83 83 **Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current sensor reference line" assignment. 84 84 ))) 85 85 86 -== =Current sensor ===80 +== 3.3.2 Current sensor == 87 87 88 88 After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board. 89 89 ... ... @@ -115,7 +115,7 @@ 115 115 116 116 Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a reference line (zero level signal). 117 117 118 -== =Current shunt sensor ===112 +== 3.3.3 Current shunt sensor == 119 119 120 120 To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor": 121 121 ... ... @@ -137,7 +137,7 @@ 137 137 ** Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); 138 138 ** Temperature – a temperature of the shunt sensor, °C. 139 139 140 -== =Temperature sensor ===134 +== 3.3.4 Temperature sensor == 141 141 142 142 To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor": 143 143 ... ... @@ -153,7 +153,7 @@ 153 153 **Note:** Temperature sensors connected to the BMS Main 2.x and BMS Logic boards must be the same type. 154 154 ))) 155 155 156 -== =Humidity sensor ===150 +== 3.3.5 Humidity sensor == 157 157 158 158 To set the humidity sensor parameters, select the menu "Signals → Humidity sensor": 159 159 ... ... @@ -163,7 +163,7 @@ 163 163 164 164 * Type – type of the humidity sensor. 165 165 166 -== =Output signals ===160 +== 3.3.6 Output signals == 167 167 168 168 The BMS Main 2.x board has **4 discrete outputs**. For each discrete output, its purpose and inversion requirement are specified. 169 169 ... ... @@ -231,9 +231,9 @@ 231 231 232 232 If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 233 233 234 -If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc: Battery managementystems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).228 +If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 235 235 236 -If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc: Battery managementystems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).230 +If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 237 237 238 238 If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[Discharging (AUX) control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischarging(AUX)control"]]). 239 239