Content
... ... @@ -1,11 +1,5 @@
1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Configuration =
1 +== 3.3.1 Input signals ==
3 3  
4 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 -== Input and output signals ==
6 -
7 -=== Input signals ===
8 -
9 9  The BMS Main 2.x board has **4 discrete inputs** of the "dry contact" type. For each discrete input, its purpose and the inversion requirement are specified.
10 10  
11 11  BMS Main 2.x board has **4 analog inputs** for connecting current, temperature and humidity sensors.
... ... @@ -83,7 +83,7 @@
83 83  **Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current sensor reference line" assignment.
84 84  )))
85 85  
86 -=== Current sensor ===
80 +== 3.3.2 Current sensor ==
87 87  
88 88  After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board.
89 89  
... ... @@ -115,7 +115,7 @@
115 115  
116 116  Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a reference line (zero level signal).
117 117  
118 -=== Current shunt sensor ===
112 +== 3.3.3 Current shunt sensor ==
119 119  
120 120  To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor":
121 121  
... ... @@ -137,7 +137,7 @@
137 137  ** Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements);
138 138  ** Temperature – a temperature of the shunt sensor, °C.
139 139  
140 -=== Temperature sensor ===
134 +== 3.3.4 Temperature sensor ==
141 141  
142 142  To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor":
143 143  
... ... @@ -153,7 +153,7 @@
153 153  **Note:** Temperature sensors connected to the BMS Main 2.x and BMS Logic boards must be the same type.
154 154  )))
155 155  
156 -=== Humidity sensor ===
150 +== 3.3.5 Humidity sensor ==
157 157  
158 158  To set the humidity sensor parameters, select the menu "Signals → Humidity sensor":
159 159  
... ... @@ -163,7 +163,7 @@
163 163  
164 164  * Type – type of the humidity sensor.
165 165  
166 -=== Output signals ===
160 +== 3.3.6 Output signals ==
167 167  
168 168  The BMS Main 2.x board has **4 discrete outputs**. For each discrete output, its purpose and inversion requirement are specified.
169 169