Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main 2\.1.3\. Configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,11 +1,5 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration = 1 +== 3.3.1 Input signals == 3 3 4 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -== Input and output signals == 6 - 7 -=== Input signals === 8 - 9 9 The BMS Main 2.x board has **4 discrete inputs** of the "dry contact" type. For each discrete input, its purpose and the inversion requirement are specified. 10 10 11 11 BMS Main 2.x board has **4 analog inputs** for connecting current, temperature and humidity sensors. ... ... @@ -83,7 +83,7 @@ 83 83 **Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current sensor reference line" assignment. 84 84 ))) 85 85 86 -== =Current sensor ===80 +== 3.3.2 Current sensor == 87 87 88 88 After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board. 89 89 ... ... @@ -115,7 +115,7 @@ 115 115 116 116 Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a reference line (zero level signal). 117 117 118 -== =Current shunt sensor ===112 +== 3.3.3 Current shunt sensor == 119 119 120 120 To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor": 121 121 ... ... @@ -137,7 +137,7 @@ 137 137 ** Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); 138 138 ** Temperature – a temperature of the shunt sensor, °C. 139 139 140 -== =Temperature sensor ===134 +== 3.3.4 Temperature sensor == 141 141 142 142 To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor": 143 143 ... ... @@ -153,7 +153,7 @@ 153 153 **Note:** Temperature sensors connected to the BMS Main 2.x and BMS Logic boards must be the same type. 154 154 ))) 155 155 156 -== =Humidity sensor ===150 +== 3.3.5 Humidity sensor == 157 157 158 158 To set the humidity sensor parameters, select the menu "Signals → Humidity sensor": 159 159 ... ... @@ -163,7 +163,7 @@ 163 163 164 164 * Type – type of the humidity sensor. 165 165 166 -== =Output signals ===160 +== 3.3.6 Output signals == 167 167 168 168 The BMS Main 2.x board has **4 discrete outputs**. For each discrete output, its purpose and inversion requirement are specified. 169 169