Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 2\.1.3\. Configuration.WebHome1 +Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,5 +1,11 @@ 1 -== 3.3.1 Input signals == 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 2 2 4 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== Input and output signals == 6 + 7 +=== Input signals === 8 + 3 3 The BMS Main 2.x board has **4 discrete inputs** of the "dry contact" type. For each discrete input, its purpose and the inversion requirement are specified. 4 4 5 5 BMS Main 2.x board has **4 analog inputs** for connecting current, temperature and humidity sensors. ... ... @@ -10,39 +10,23 @@ 10 10 11 11 [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]] 12 12 13 -** Discrete inputs** inthis section:19 +A list of available **discrete input assignments **is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 14 14 15 -* No input; 16 -* Battery cover – a signal from the battery cover trailer; 17 -* Charger connected – a signal from the charger connector; 18 -* Power up/down request – a signal from the external power monitor which is used for proper powering BMS up or down; 19 -* Inhibit charging – a command to open the charging relay; 20 -* Inhibit discharging – a command to open the discharging relay; 21 -* CH contactor feedback – a feedback signal from the charging contactor; 22 -* DCH contactor feedback – a feedback signal from the discharging contactor; 23 -* Insulation status – a signal from an external insulation monitoring device; 24 -* Charge request – a request for closing the charging contactor; 25 -* Precharge request – a request for closing the precharging contactor; 26 -* Discharge request – a request for closing the discharging contactor; 27 -* PCH contactor feedback – a feedback signal from the precharging contactor; 28 -* CH/DCH contactor feedback – a feedback signal from the charging/discharging contactor; 29 -* Main contactor feedback – a feedback signal from the main contactor. 21 +If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[Battery cover protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]). 30 30 31 - If the "Signal from thebatterycover" assignment is selected, the discrete input isused tomonitorthe state ofthebatterycover(see[[Battery coverprotection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6Batteryprotection.WebHome||anchor="HBatterycoverprotection"]]).23 +if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 32 32 33 - if the "Chargerconnected" assignment is selected, the discrete input is involved in the algorithms of chargeand discharge control (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).25 +If the "Power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 34 34 35 -If the "Power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 36 - 37 37 If the “Inhibit charging” assignment is selected, the discrete input is used to open the charging relay. 38 38 39 39 If the “Inhibit discharging” assignment is selected, the discrete input is used to open the discharging relay. 40 40 41 -If the “CH contactor feedback”, “DCH contactor feedback”, “PCH contactor feedback”, “CH/DCH contactor feedback” or “Main contactor feedback” assignment is selected, the discrete input is involved in monitoring the corresponding contactor’s feedback signal (see [[Contactor feedback check>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HContactorfeedbackcheck"]]).31 +If the “CH contactor feedback”, “DCH contactor feedback”, “PCH contactor feedback”, “CH/DCH contactor feedback” or “Main contactor feedback” assignment is selected, the discrete input is involved in monitoring the corresponding contactor’s feedback signal (see [[Contactor feedback check>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HContactorfeedbackcheck"]]). 42 42 43 -If the “Charge request”, “Precharge request” or “Discharge request” assignment is selected, the discrete input is used to control opening the corresponding contactor (see [[Charge control>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).33 +If the “Charge request”, “Precharge request” or “Discharge request” assignment is selected, the discrete input is used to control opening the corresponding contactor (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 44 44 45 -If the “Insulation status” assignment is selected, the discrete input is used to monitor a signal from an external insulation monitoring device (see [[Insulation monitoring>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HInsulationmonitoring"]]).35 +If the “Insulation status” assignment is selected, the discrete input is used to monitor a signal from an external insulation monitoring device (see [[Insulation monitoring>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HInsulationmonitoring"]]). 46 46 47 47 48 48 **Analog inputs** in this section: ... ... @@ -64,7 +64,7 @@ 64 64 65 65 (% class="box warningmessage" %) 66 66 ((( 67 -**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).57 +**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 68 68 ))) 69 69 70 70 (% class="box warningmessage" %) ... ... @@ -77,7 +77,7 @@ 77 77 **Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current sensor reference line" assignment. 78 78 ))) 79 79 80 -== 3.3.2Current sensor ==70 +=== Current sensor === 81 81 82 82 After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board. 83 83 ... ... @@ -109,7 +109,7 @@ 109 109 110 110 Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a reference line (zero level signal). 111 111 112 -== 3.3.3Current shunt sensor ==102 +=== Current shunt sensor === 113 113 114 114 To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor": 115 115 ... ... @@ -131,7 +131,7 @@ 131 131 ** Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); 132 132 ** Temperature – a temperature of the shunt sensor, °C. 133 133 134 -== 3.3.4Temperature sensor ==124 +=== Temperature sensor === 135 135 136 136 To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor": 137 137 ... ... @@ -139,8 +139,8 @@ 139 139 140 140 In this section: 141 141 142 -* Type – type of temperature sensors .143 -* Mask -132 +* Type – type of temperature sensors; 133 +* Mask – mask to ignore the temperature from the corresponding temperature sensors; bit //i// corresponds to temperature input //#(i+1)// of each BMS Logic device; mask 0x5 means that the BMS marks all temperature sensors connected to inputs #1 and #3 of each BMS Logic device as missing and doesn't use them in calculations. 144 144 145 145 (% class="box infomessage" %) 146 146 ((( ... ... @@ -147,7 +147,7 @@ 147 147 **Note:** Temperature sensors connected to the BMS Main 2.x and BMS Logic boards must be the same type. 148 148 ))) 149 149 150 -== 3.3.5Humidity sensor ==140 +=== Humidity sensor === 151 151 152 152 To set the humidity sensor parameters, select the menu "Signals → Humidity sensor": 153 153 ... ... @@ -157,7 +157,7 @@ 157 157 158 158 * Type – type of the humidity sensor. 159 159 160 -== 3.3.6Output signals ==150 +=== Output signals === 161 161 162 162 The BMS Main 2.x board has **4 discrete outputs**. For each discrete output, its purpose and inversion requirement are specified. 163 163 ... ... @@ -169,35 +169,25 @@ 169 169 170 170 [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]] 171 171 172 -** Discreteoutputs** inthis section:162 +A list of available **discrete input assignments **is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 173 173 174 -* No output; 175 -* Low SOC; 176 -* High charging current; 177 -* Cooler; 178 -* Heater; 179 -* Allow charging; 180 -* Precharging; 181 -* Acknowledgement of power down; 182 -* Power up; 164 +If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[Low SOC signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]). 183 183 184 -If the " LowSOC" assignment is selected, the output indicates the low batterychargelevel (see [[LowSOCsignal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]).166 +If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see [[High charging current signal>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHighchargingcurrentsignal"]]). 185 185 186 -If the " High battery charge current" assignment is selected, the output indicates that thechargingcurrentexceedsthepredefined value (see [[Highchargingcurrentsignal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHighchargingcurrentsignal"]]).168 +If the "Cooler" assignment is selected, the output indicates the overheating of the battery (see [[High temperature protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHightemperatureprotection"]]). 187 187 188 -If the " Cooler" assignment is selected, the output indicates the overheatingof thebattery (see [[Hightemperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHightemperatureprotection"]]).170 +If the "Heater" assignment is selected, the output indicates the low battery temperature signal (see [[Low temperature protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowtemperatureprotection"]]). 189 189 190 -If the " Heater" assignment is selected, the output indicatesthe lowbatterytemperaturesignal(see [[Low temperatureprotection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6Batteryprotection.WebHome||anchor="HLowtemperatureprotection"]]).172 +If the "Allow charging" assignment is selected, the output is used to give the charger the allowance to charge the battery (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 191 191 192 -If the " Allowcharging" assignment is selected, the output is used togive thechargerthe allowancetochargethe battery(see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]).174 +If the "Precharging" assignment is selected, the output is used to charge the capacitive load (see [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 193 193 194 -If the " Precharging" assignment is selected, the output is used tocharge the capacitive load (see [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).176 +If the "Acknowledgement of power down" assignment is selected, the output is used to acknowledge power down of the BMS. Acknowledgement is outputted when the charge and discharge relays have been opened on power down request (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 195 195 196 -If the " Acknowledgement of powerdown" assignment is selected, the output is used toacknowledge powerdownoftheBMS.Acknowledgement isoutputted whenthe charge and discharge relays have beenopened on power downrequest (see [[Chargecontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Batterycontrol.WebHome||anchor="HChargecontrol"]]and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Batterycontrol.WebHome||anchor="HDischargecontrol"]]).178 +If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[Power down control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HPowerdowncontrol"]]). 197 197 198 -If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[Power down control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HPowerdowncontrol"]]). 199 199 200 - 201 201 **Relay assignments** in this section: 202 202 203 203 * No relay; ... ... @@ -213,23 +213,23 @@ 213 213 * Main contactor; 214 214 * Power up. 215 215 216 -If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charge control>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]).196 +If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 217 217 218 -If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[Discharge control>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).198 +If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 219 219 220 -If the "Allow charging" assignment is selected, the relay is used to give the charger an allowance to charge the battery (see [[Charge control>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]).200 +If the "Allow charging" assignment is selected, the relay is used to give the charger an allowance to charge the battery (see [[Charge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 221 221 222 -If the "Cooler" assignment is selected, the relay receives a signal indicating overheating of the battery (see [[High temperature protection>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHightemperatureprotection"]]) or the signal "Cooler" (see [[Cooler control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HCoolercontrol"]]).202 +If the "Cooler" assignment is selected, the relay receives a signal indicating overheating of the battery (see [[High temperature protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHightemperatureprotection"]]) or the signal "Cooler" (see [[Cooler control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HCoolercontrol"]]). 223 223 224 -If the "Heater" assignment is selected, a low battery temperature signal is outputted to the relay (see [[Low temperature protection>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowtemperatureprotection"]]) or a signal "Heater" (see [[Heater control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHeatercontrol"]]).204 +If the "Heater" assignment is selected, a low battery temperature signal is outputted to the relay (see [[Low temperature protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowtemperatureprotection"]]) or a signal "Heater" (see [[Heater control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHeatercontrol"]]). 225 225 226 -If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[Discharge control>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]).206 +If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[Discharge control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 227 227 228 -If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).208 +If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 229 229 230 -If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).210 +If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 231 231 232 -If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[Discharging (AUX) control>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischarging(AUX)control"]]).212 +If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[Discharging (AUX) control>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischarging(AUX)control"]]). 233 233 234 234 If the "Main contactor" assignment is selected, the relay is used to close the main contactor in the common (minus) power bus. 235 235
- 1736458361419-177.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.3 KB - Content