Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 2\.1.3\. Configuration.WebHome1 +Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,5 +1,11 @@ 1 -== 3.3.1 Input signals == 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 2 2 4 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== Input and output signals == 6 + 7 +=== Input signals === 8 + 3 3 The BMS Main 2.x board has **4 discrete inputs** of the "dry contact" type. For each discrete input, its purpose and the inversion requirement are specified. 4 4 5 5 BMS Main 2.x board has **4 analog inputs** for connecting current, temperature and humidity sensors. ... ... @@ -64,7 +64,7 @@ 64 64 65 65 (% class="box warningmessage" %) 66 66 ((( 67 -**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).73 +**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 68 68 ))) 69 69 70 70 (% class="box warningmessage" %) ... ... @@ -77,7 +77,7 @@ 77 77 **Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current sensor reference line" assignment. 78 78 ))) 79 79 80 -== 3.3.2Current sensor ==86 +=== Current sensor === 81 81 82 82 After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board. 83 83 ... ... @@ -109,7 +109,7 @@ 109 109 110 110 Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a reference line (zero level signal). 111 111 112 -== 3.3.3Current shunt sensor ==118 +=== Current shunt sensor === 113 113 114 114 To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor": 115 115 ... ... @@ -131,7 +131,7 @@ 131 131 ** Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); 132 132 ** Temperature – a temperature of the shunt sensor, °C. 133 133 134 -== 3.3.4Temperature sensor ==140 +=== Temperature sensor === 135 135 136 136 To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor": 137 137 ... ... @@ -147,7 +147,7 @@ 147 147 **Note:** Temperature sensors connected to the BMS Main 2.x and BMS Logic boards must be the same type. 148 148 ))) 149 149 150 -== 3.3.5Humidity sensor ==156 +=== Humidity sensor === 151 151 152 152 To set the humidity sensor parameters, select the menu "Signals → Humidity sensor": 153 153 ... ... @@ -157,7 +157,7 @@ 157 157 158 158 * Type – type of the humidity sensor. 159 159 160 -== 3.3.6Output signals ==166 +=== Output signals === 161 161 162 162 The BMS Main 2.x board has **4 discrete outputs**. For each discrete output, its purpose and inversion requirement are specified. 163 163 ... ... @@ -225,9 +225,9 @@ 225 225 226 226 If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 227 227 228 -If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).234 +If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 229 229 230 -If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc: drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]).236 +If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 231 231 232 232 If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[Discharging (AUX) control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischarging(AUX)control"]]). 233 233