Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 2\.1.3\. Configuration.WebHome1 +Battery management systems.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -1,5 +1,11 @@ 1 -== 3.3.1 Input signals == 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 2 2 4 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== Input and output signals == 6 + 7 +=== Input signals === 8 + 3 3 The BMS Main 2.x board has **4 discrete inputs** of the "dry contact" type. For each discrete input, its purpose and the inversion requirement are specified. 4 4 5 5 BMS Main 2.x board has **4 analog inputs** for connecting current, temperature and humidity sensors. ... ... @@ -77,7 +77,7 @@ 77 77 **Note:** The default setting for Analog input #2 is "No signal". If it is necessary to use a current sensor with an additional zero level signal, set the "Current sensor reference line" assignment. 78 78 ))) 79 79 80 -== 3.3.2Current sensor ==86 +=== Current sensor === 81 81 82 82 After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board. 83 83 ... ... @@ -109,7 +109,7 @@ 109 109 110 110 Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a reference line (zero level signal). 111 111 112 -== 3.3.3Current shunt sensor ==118 +=== Current shunt sensor === 113 113 114 114 To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor": 115 115 ... ... @@ -131,7 +131,7 @@ 131 131 ** Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); 132 132 ** Temperature – a temperature of the shunt sensor, °C. 133 133 134 -== 3.3.4Temperature sensor ==140 +=== Temperature sensor === 135 135 136 136 To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor": 137 137 ... ... @@ -147,7 +147,7 @@ 147 147 **Note:** Temperature sensors connected to the BMS Main 2.x and BMS Logic boards must be the same type. 148 148 ))) 149 149 150 -== 3.3.5Humidity sensor ==156 +=== Humidity sensor === 151 151 152 152 To set the humidity sensor parameters, select the menu "Signals → Humidity sensor": 153 153 ... ... @@ -157,7 +157,7 @@ 157 157 158 158 * Type – type of the humidity sensor. 159 159 160 -== 3.3.6Output signals ==166 +=== Output signals === 161 161 162 162 The BMS Main 2.x board has **4 discrete outputs**. For each discrete output, its purpose and inversion requirement are specified. 163 163