Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -28,21 +28,21 @@ 28 28 * CH/DCH contactor feedback – a feedback signal from the charging/discharging contactor; 29 29 * Main contactor feedback – a feedback signal from the main contactor. 30 30 31 -If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[Battery cover protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]). 31 +If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[3.6.6 Battery cover protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.6Batterycoverprotection"]]). 32 32 33 -if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 33 +if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see [[3.5.1 Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.1Chargecontrol"]] and [[3.5.2 Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]). 34 34 35 -If the "Power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 35 +If the "Power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see [[3.5.1 Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.1Chargecontrol"]] and [[3.5.2 Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]). 36 36 37 37 If the “Inhibit charging” assignment is selected, the discrete input is used to open the charging relay. 38 38 39 39 If the “Inhibit discharging” assignment is selected, the discrete input is used to open the discharging relay. 40 40 41 -If the “CH contactor feedback”, “DCH contactor feedback”, “PCH contactor feedback”, “CH/DCH contactor feedback” or “Main contactor feedback” assignment is selected, the discrete input is involved in monitoring the corresponding contactor’s feedback signal (see [[Contactor feedback check>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HContactorfeedbackcheck"]]). 41 +If the “CH contactor feedback”, “DCH contactor feedback”, “PCH contactor feedback”, “CH/DCH contactor feedback” or “Main contactor feedback” assignment is selected, the discrete input is involved in monitoring the corresponding contactor’s feedback signal (see [[3.6.14 Contactor feedback check>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.14Contactorfeedbackcheck"]]). 42 42 43 -If the “Charge request”, “Precharge request” or “Discharge request” assignment is selected, the discrete input is used to control opening the corresponding contactor (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 43 +If the “Charge request”, “Precharge request” or “Discharge request” assignment is selected, the discrete input is used to control opening the corresponding contactor (see [[3.5.1 Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.1Chargecontrol"]] and [[3.5.2 Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]). 44 44 45 -If the “Insulation status” assignment is selected, the discrete input is used to monitor a signal from an external insulation monitoring device (see [[Insulation monitoring>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HInsulationmonitoring"]]). 45 +If the “Insulation status” assignment is selected, the discrete input is used to monitor a signal from an external insulation monitoring device (see [[3.6.23 Insulation monitoring>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.23Insulationmonitoring"]]). 46 46 47 47 48 48 **Analog inputs** in this section: ... ... @@ -64,7 +64,7 @@ 64 64 65 65 (% class="box warningmessage" %) 66 66 ((( 67 -**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 67 +**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[3.4.5 Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="H3.4.5Seriesbalancing"]]). 68 68 ))) 69 69 70 70 (% class="box warningmessage" %) ... ... @@ -181,21 +181,21 @@ 181 181 * Acknowledgement of power down; 182 182 * Power up; 183 183 184 -If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[Low SOC signal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]). 184 +If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[3.6.26 Low SOC signal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.26LowSOCsignal"]]). 185 185 186 -If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see [[High charging current signal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHighchargingcurrentsignal"]]). 186 +If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see [[3.6.27 High charging current signal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.27Highchargingcurrentsignal"]]). 187 187 188 -If the "Cooler" assignment is selected, the output indicates the overheating of the battery (see [[High temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHightemperatureprotection"]]). 188 +If the "Cooler" assignment is selected, the output indicates the overheating of the battery (see [[3.6.5 High temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.5Hightemperatureprotection"]]). 189 189 190 -If the "Heater" assignment is selected, the output indicates the low battery temperature signal (see [[Low temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowtemperatureprotection"]]). 190 +If the "Heater" assignment is selected, the output indicates the low battery temperature signal (see [[3.6.4 Low temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.4Lowtemperatureprotection"]]). 191 191 192 -If the "Allow charging" assignment is selected, the output is used to give the charger the allowance to charge the battery (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 192 +If the "Allow charging" assignment is selected, the output is used to give the charger the allowance to charge the battery (see [[3.5.1 Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]). 193 193 194 -If the "Precharging" assignment is selected, the output is used to charge the capacitive load (see [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 194 +If the "Precharging" assignment is selected, the output is used to charge the capacitive load (see [[3.5.2 Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]). 195 195 196 -If the "Acknowledgement of power down" assignment is selected, the output is used to acknowledge power down of the BMS. Acknowledgement is outputted when the charge and discharge relays have been opened on power down request (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 196 +If the "Acknowledgement of power down" assignment is selected, the output is used to acknowledge power down of the BMS. Acknowledgement is outputted when the charge and discharge relays have been opened on power down request (see [[3.5.1 Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.1Chargecontrol"]] and [[3.5.2 Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]). 197 197 198 -If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[Power down control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HPowerdowncontrol"]]). 198 +If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[3.5.6 Power down control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.5.6Powerdowncontrol"]]). 199 199 200 200 201 201 **Relay assignments** in this section: ... ... @@ -213,23 +213,23 @@ 213 213 * Main contactor; 214 214 * Power up. 215 215 216 -If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 216 +If the "Charging" assignment is selected, the relay is used to charge the battery (see [[3.5.1 Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]). 217 217 218 -If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 218 +If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[3.5.2 Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]). 219 219 220 -If the "Allow charging" assignment is selected, the relay is used to give the charger an allowance to charge the battery (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 220 +If the "Allow charging" assignment is selected, the relay is used to give the charger an allowance to charge the battery (see [[3.5.1 Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]). 221 221 222 -If the "Cooler" assignment is selected, the relay receives a signal indicating overheating of the battery (see [[High temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHightemperatureprotection"]]) or the signal "Cooler" (see [[Cooler control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HCoolercontrol"]]). 222 +If the "Cooler" assignment is selected, the relay receives a signal indicating overheating of the battery (see [[3.6.5 High temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.5Hightemperatureprotection"]]) or the signal "Cooler" (see [[3.6.30 Cooler control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.30Coolercontrol"]]). 223 223 224 -If the "Heater" assignment is selected, a low battery temperature signal is outputted to the relay (see [[Low temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowtemperatureprotection"]]) or a signal "Heater" (see [[Heater control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHeatercontrol"]]). 224 +If the "Heater" assignment is selected, a low battery temperature signal is outputted to the relay (see [[3.6.4 Low temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.4Lowtemperatureprotection"]]) or a signal "Heater" (see [[3.6.28 Heater control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.28Heatercontrol"]]). 225 225 226 -If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 226 +If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[3.5.2 Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]). 227 227 228 -If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 228 +If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[3.4.5 Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="H3.4.5Seriesbalancing"]]). 229 229 230 -If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 230 +If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[3.4.5 Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="H3.4.5Seriesbalancing"]]). 231 231 232 -If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[Discharging (AUX) control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischarging(AUX)control"]]). 232 +If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[3.5.3 Discharging (AUX) control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.3Discharging(AUX)control"]]). 233 233 234 234 If the "Main contactor" assignment is selected, the relay is used to close the main contactor in the common (minus) power bus. 235 235