Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,7 +10,7 @@ 10 10 11 11 [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]] 12 12 13 - **Discrete inputs**in this section:13 +Discrete inputs in this section: 14 14 15 15 * No input; 16 16 * Battery cover – a signal from the battery cover trailer; ... ... @@ -28,24 +28,24 @@ 28 28 * CH/DCH contactor feedback – a feedback signal from the charging/discharging contactor; 29 29 * Main contactor feedback – a feedback signal from the main contactor. 30 30 31 -If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[3.6.6 Batterycover protection>>doc:drafts.BMSMain 2\.1.3\. Configuration.3\.6Batteryprotection.WebHome||anchor="H3.6.6Batterycoverprotection"]]).31 +If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see section Battery cover protection). 32 32 33 -if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see [[3.5.1 Chargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]and[[3.5.2Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]).33 +if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see sections Charge control and Discharge control). 34 34 35 -If the "Power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see [[3.5.1 Chargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]and[[3.5.2Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]).35 +If the "Power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see sections Charge control and Discharge control). 36 36 37 37 If the “Inhibit charging” assignment is selected, the discrete input is used to open the charging relay. 38 38 39 39 If the “Inhibit discharging” assignment is selected, the discrete input is used to open the discharging relay. 40 40 41 -If the “CH contactor feedback”, “DCH contactor feedback”, “PCH contactor feedback”, “CH/DCH contactor feedback” or “Main contactor feedback” assignment is selected, the discrete input is involved in monitoring the corresponding contactor’s feedback signal (see [[3.6.14 Contactor feedback check>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.14Contactorfeedbackcheck"]]).41 +If the “CH contactor feedback”, “DCH contactor feedback”, “PCH contactor feedback”, “CH/DCH contactor feedback” or “Main contactor feedback” assignment is selected, the discrete input is involved in monitoring the corresponding contactor’s feedback signal (see section Contactor feedback check). 42 42 43 -If the “Charge request”, “Precharge request” or “Discharge request” assignment is selected, the discrete input is used to control opening the corresponding contactor (see [[3.5.1 Chargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]and[[3.5.2Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]).43 +If the “Charge request”, “Precharge request” or “Discharge request” assignment is selected, the discrete input is used to control opening the corresponding contactor (see sections Charge control and Discharge control). 44 44 45 -If the “Insulation status” assignment is selected, the discrete input is used to monitor a signal from an external insulation monitoring device (see [[3.6.23 Insulation monitoring>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.23Insulationmonitoring"]]).45 +If the “Insulation status” assignment is selected, the discrete input is used to monitor a signal from an external insulation monitoring device (see section Insulation monitoring). 46 46 47 47 48 - **Analog inputs**in this section:48 +Analog inputs in this section: 49 49 50 50 * No input; 51 51 * Current sensor; ... ... @@ -64,7 +64,7 @@ 64 64 65 65 (% class="box warningmessage" %) 66 66 ((( 67 -**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[3.4.5 Seriesbalancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4Battery parameters.WebHome||anchor="H3.4.5Seriesbalancing"]]).67 +**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see section Series balancing). 68 68 ))) 69 69 70 70 (% class="box warningmessage" %) ... ... @@ -169,7 +169,7 @@ 169 169 170 170 [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]] 171 171 172 - **Discrete outputs**in this section:172 +Discrete outputs in this section: 173 173 174 174 * No output; 175 175 * Low SOC; ... ... @@ -181,24 +181,24 @@ 181 181 * Acknowledgement of power down; 182 182 * Power up; 183 183 184 -If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[3.6.26 Low SOCsignal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.26LowSOCsignal"]]).184 +If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see section Low SOC signal). 185 185 186 -If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see [[3.6.27 High charging currentsignal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.27Highchargingcurrentsignal"]]).186 +If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see section High charging current signal). 187 187 188 -If the "Cooler" assignment is selected, the output indicates the overheating of the battery (see [[3.6.5 High temperature protection>>doc:drafts.BMSMain 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.5Hightemperatureprotection"]]).188 +If the "Cooler" assignment is selected, the output indicates the overheating of the battery (see section Temperature protection). 189 189 190 -If the "Heater" assignment is selected, the output indicates the low battery temperature signal (see [[3.6.4 Low temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.4Lowtemperatureprotection"]]).190 +If the "Heater" assignment is selected, the output indicates the low battery temperature signal (see section Temperature protection). 191 191 192 -If the "Allow charging" assignment is selected, the output is used to give the charger the allowance to charge the battery (see [[3.5.1 Chargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]).192 +If the "Allow charging" assignment is selected, the output is used to give the charger the allowance to charge the battery (see section Charge control). 193 193 194 -If the "Precharging" assignment is selected, the output is used to charge the capacitive load (see [[3.5.2 Dischargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]).194 +If the "Precharging" assignment is selected, the output is used to charge the capacitive load (see section Discharge control). 195 195 196 -If the "Acknowledgement of power down" assignment is selected, the output is used to acknowledge power down of the BMS. Acknowledgement is outputted when the charge and discharge relays have been opened on power down request (see [[3.5.1 Chargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]and[[3.5.2Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]).196 +If the "Acknowledgement of power down" assignment is selected, the output is used to acknowledge power down of the BMS. Acknowledgement is outputted when the charge and discharge relays have been opened on power down request (see sections Charge control and Discharge control). 197 197 198 -If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[3.5.6 Power down control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.5.6Powerdowncontrol"]]).198 +If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see section Power down control). 199 199 200 200 201 - **Relay assignments**in this section:201 +Relay assignments in this section: 202 202 203 203 * No relay; 204 204 * Charging; ... ... @@ -213,23 +213,23 @@ 213 213 * Main contactor; 214 214 * Power up. 215 215 216 -If the "Charging" assignment is selected, the relay is used to charge the battery (see [[3.5.1 Chargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]).216 +If the "Charging" assignment is selected, the relay is used to charge the battery (see section Charge control). 217 217 218 -If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[3.5.2 Dischargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]).218 +If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see section Discharge control). 219 219 220 -If the "Allow charging" assignment is selected, the relay is used to give the charger an allowance to charge the battery (see [[3.5.1 Chargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.1Chargecontrol"]]).220 +If the "Allow charging" assignment is selected, the relay is used to give the charger an allowance to charge the battery (see section Charge control). 221 221 222 -If the "Cooler" assignment is selected, the relay receives a signal indicating overheating of the battery (see [[3.6.5 High temperature protection>>doc:drafts.BMSMain 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.5Hightemperatureprotection"]]) or the signal "Cooler" (see[[3.6.30 Cooler control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.30Coolercontrol"]]).222 +If the "Cooler" assignment is selected, the relay receives a signal indicating overheating of the battery (see section Temperature protection) or the signal "Cooler" (see section Cooler control). 223 223 224 -If the "Heater" assignment is selected, a low battery temperature signal is outputted to the relay (see [[3.6.4 Low temperature protection>>doc:drafts.BMSMain 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.4Lowtemperatureprotection"]]) or a signal "Heater" (see[[3.6.28 Heater control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="H3.6.28Heatercontrol"]]).224 +If the "Heater" assignment is selected, a low battery temperature signal is outputted to the relay (see section Temperature protection) or a signal "Heater" (see section Heater control). 225 225 226 -If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[3.5.2 Dischargeontrol>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.2Dischargecontrol"]]).226 +If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see section Discharge control). 227 227 228 -If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[3.4.5 Seriesbalancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4Battery parameters.WebHome||anchor="H3.4.5Seriesbalancing"]]).228 +If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see section Series balancing). 229 229 230 -If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[3.4.5 Seriesbalancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4Battery parameters.WebHome||anchor="H3.4.5Seriesbalancing"]]).230 +If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see section Series balancing). 231 231 232 -If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[3.5.3 Discharging (AUX) control>>doc:drafts.BMSMain 2\.1.3\. Configuration.3\.5Battery control.WebHome||anchor="H3.5.3Discharging(AUX)control"]]).232 +If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see section Powering external equipment). 233 233 234 234 If the "Main contactor" assignment is selected, the relay is used to close the main contactor in the common (minus) power bus. 235 235