Last modified by Admin on 2025/04/09 12:34

From version 17.1
edited by Admin
on 2024/12/02 15:09
Change comment: There is no comment for this version
To version 14.1
edited by Admin
on 2024/11/28 11:44
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.BMS Main 2\.1.3\. Configuration.WebHome
1 +drafts.bms-main-2.configuration.WebHome
Content
... ... @@ -4,12 +4,12 @@
4 4  
5 5  BMS Main 2.x board has **4 analog inputs** for connecting current, temperature and humidity sensors.
6 6  
7 -The order of the numbering of the discrete and analog inputs corresponds to the order of the numbering on the board.
8 -
9 9  (% id="cke_bm_2415S" style="display:none" %) (%%)To configure the input discrete and analog signals, select the menu "Signals → Input signals":
10 10  
11 -[[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]]
9 +[[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" height="290" width="272"]]
12 12  
11 +The order of the numbering of the discrete and analog inputs corresponds to the order of the numbering on the board.
12 +
13 13  Discrete inputs in this section:
14 14  
15 15  * No input;
... ... @@ -83,8 +83,9 @@
83 83  
84 84  To configure the current sensor parameters, select the menu "Signals → Current sensor":
85 85  
86 -[[image:1732202357233-620.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="453" width="284"]]
86 +[[image:1732202357233-620.png||data-xwiki-image-style-alignment="center" height="453" width="284"]]
87 87  
88 +
88 88  In the «Primary sensor» и «Auxiliary sensor» sections:
89 89  
90 90  * Sensor type – drop-down menu with supported sensor types;
... ... @@ -113,17 +113,17 @@
113 113  
114 114  To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor":
115 115  
116 -[[image:1732202640889-562.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="342" width="265"]]
117 +[[image:1732202640889-562.png||data-xwiki-image-style-alignment="center" height="342" width="265"]]
117 117  
118 118  In this section:
119 119  
120 120  * Settings:
121 -** Enable – a flag to start interaction with BMS Current Sensor (if interaction is enabled then BMS doesn’t use Hall-Effect current sensor which settings are described in the menu "Signals → Current sensor");
122 -** Node ID – an address of BMS Current Sensor in CANopen network;
123 -** Dispatch timeout – timeout of dispatching packages from BMS Current Sensor (if no data is being received from current sensor during this time, the “Shunt offline” flag is set), millisecond;
124 -** Zero level threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is lower than T,,0,,, BMS will assume that current flowing through the battery is zero);
125 -** Mean level threshold – TM level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is between T,,M,, and T,,0,,, BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, BMS will use instantaneous value of current I,,I,,);
126 -** Invert – a flag to invert current values;
122 +* Enable – a flag to start interaction with BMS Current Sensor (if interaction is enabled then BMS doesn’t use Hall-Effect current sensor which settings are described in the menu "Signals → Current sensor");
123 +* Node ID – an address of BMS Current Sensor in CANopen network;
124 +* Dispatch timeout – timeout of dispatching packages from BMS Current Sensor (if no data is being received from current sensor during this time, the “Shunt offline” flag is set), millisecond;
125 +* Zero level threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is lower than T,,0,,, BMS will assume that current flowing through the battery is zero);
126 +* Mean level threshold – TM level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is between T,,M,, and T,,0,,, BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, BMS will use instantaneous value of current I,,I,,);
127 +* Invert – a flag to invert current values;
127 127  * Sensor state:
128 128  ** Online – a flag showing that the communication with the BMS Current Sensor is established;
129 129  ** Errors – a list of internal errors of the shunt sensor;
... ... @@ -135,8 +135,9 @@
135 135  
136 136  To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor":
137 137  
138 -[[image:1732204766138-628.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="256"]]
139 +[[image:1732204766138-628.png||data-xwiki-image-style-alignment="center" height="112" width="256"]]
139 139  
141 +
140 140  In this section:
141 141  
142 142  * Type – type of temperature sensors.
... ... @@ -151,7 +151,7 @@
151 151  
152 152  To set the humidity sensor parameters, select the menu "Signals → Humidity sensor":
153 153  
154 -[[image:1732204899160-307.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="195"]]
156 +[[Humidity sensor settings>>image:1732204899160-307.png||data-xwiki-image-style-alignment="center" height="120" width="195"]]
155 155  
156 156   In this section:
157 157  
... ... @@ -159,16 +159,17 @@
159 159  
160 160  == 3.3.6 Output signals ==
161 161  
162 -The BMS Main 2.x board has **4 discrete outputs**. For each discrete output, its purpose and inversion requirement are specified.
164 +The BMS Main 2.x board has 4 discrete outputs. For each discrete output, its purpose and inversion requirement are specified.
163 163  
164 -The BMS Main 2.x board has **4 solid-state relays** (#1 and #2 of them are bipolar, and the #3 and #4 are unipolar). For each relay, its purpose and inversion requirement are specified.
166 +The BMS Main 2.x board has 4 solid-state relays (#1 and #2 of them are bipolar, and the #3 and #4 are unipolar). For each relay, its purpose and inversion requirement are specified.
165 165  
166 -The order of the numbering of the discrete outputs and the relay corresponds to the order of the numbering on the board.
167 -
168 168  To configure output discrete signals and relays, select the menu "Signals → Output signals":
169 169  
170 -[[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]]
170 +[[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" height="346" width="295"]]
171 171  
172 +
173 +The order of the numbering of the discrete outputs and the relay corresponds to the order of the numbering on the board.
174 +
172 172  Discrete outputs in this section:
173 173  
174 174  * No output;
1732794334071-303.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -60.3 KB
Content