5 5  BMS Main 2.x board has **4 analog inputs** for connecting current, temperature and humidity sensors.
6 6  
7 -The order of the numbering of the discrete and analog inputs corresponds to the order of the numbering on the board.
8 -
9 9  (% id="cke_bm_2415S" style="display:none" %) (%%)To configure the input discrete and analog signals, select the menu "Signals → Input signals":
10 10  
11 11  [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" height="290" width="272"]]
12 12  
11 +The order of the numbering of the discrete and analog inputs corresponds to the order of the numbering on the board.
13 13  
14 14  Discrete inputs in this section:
15 15  
... ... @@ -86,6 +86,7 @@
86 86  
87 87  [[image:1732202357233-620.png||data-xwiki-image-style-alignment="center" height="453" width="284"]]
88 88  
88 +
89 89  In the «Primary sensor» и «Auxiliary sensor» sections:
90 90  
91 91  * Sensor type – drop-down menu with supported sensor types;
... ... @@ -119,12 +119,12 @@
119 119  In this section:
120 120  
121 121  * Settings:
122 -** Enable – a flag to start interaction with BMS Current Sensor (if interaction is enabled then BMS doesn’t use Hall-Effect current sensor which settings are described in the menu "Signals → Current sensor");
123 -** Node ID – an address of BMS Current Sensor in CANopen network;
124 -** Dispatch timeout – timeout of dispatching packages from BMS Current Sensor (if no data is being received from current sensor during this time, the “Shunt offline” flag is set), millisecond;
125 -** Zero level threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is lower than T,,0,,, BMS will assume that current flowing through the battery is zero);
126 -** Mean level threshold – TM level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is between T,,M,, and T,,0,,, BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, BMS will use instantaneous value of current I,,I,,);
127 -** Invert – a flag to invert current values;
122 +* Enable – a flag to start interaction with BMS Current Sensor (if interaction is enabled then BMS doesn’t use Hall-Effect current sensor which settings are described in the menu "Signals → Current sensor");
123 +* Node ID – an address of BMS Current Sensor in CANopen network;
124 +* Dispatch timeout – timeout of dispatching packages from BMS Current Sensor (if no data is being received from current sensor during this time, the “Shunt offline” flag is set), millisecond;
125 +* Zero level threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is lower than T,,0,,, BMS will assume that current flowing through the battery is zero);
126 +* Mean level threshold – TM level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is between T,,M,, and T,,0,,, BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, BMS will use instantaneous value of current I,,I,,);
127 +* Invert – a flag to invert current values;
128 128  * Sensor state:
129 129  ** Online – a flag showing that the communication with the BMS Current Sensor is established;
130 130  ** Errors – a list of internal errors of the shunt sensor;
... ... @@ -138,6 +138,7 @@
138 138  
139 139  [[image:1732204766138-628.png||data-xwiki-image-style-alignment="center" height="112" width="256"]]
140 140  
141 +
141 141  In this section:
142 142  
143 143  * Type – type of temperature sensors.
... ... @@ -152,7 +152,7 @@
152 152  
153 153  To set the humidity sensor parameters, select the menu "Signals → Humidity sensor":
154 154  
155 -[[image:1732204899160-307.png||data-xwiki-image-style-alignment="center" height="120" width="195"]]
156 +[[Humidity sensor settings>>image:1732204899160-307.png||data-xwiki-image-style-alignment="center" height="120" width="195"]]
156 156  
157 157   In this section:
158 158  
... ... @@ -160,16 +160,17 @@
160 160  
161 161  == 3.3.6 Output signals ==
162 162  
163 -The BMS Main 2.x board has **4 discrete outputs**. For each discrete output, its purpose and inversion requirement are specified.
164 +The BMS Main 2.x board has 4 discrete outputs. For each discrete output, its purpose and inversion requirement are specified.
164 164  
165 -The BMS Main 2.x board has **4 solid-state relays** (#1 and #2 of them are bipolar, and the #3 and #4 are unipolar). For each relay, its purpose and inversion requirement are specified.
166 +The BMS Main 2.x board has 4 solid-state relays (#1 and #2 of them are bipolar, and the #3 and #4 are unipolar). For each relay, its purpose and inversion requirement are specified.
166 166  
167 -The order of the numbering of the discrete outputs and the relay corresponds to the order of the numbering on the board.
168 -
169 169  To configure output discrete signals and relays, select the menu "Signals → Output signals":
170 170  
171 171  [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" height="346" width="295"]]
172 172  
172 +
173 +The order of the numbering of the discrete outputs and the relay corresponds to the order of the numbering on the board.
174 +
173 173  Discrete outputs in this section: