Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - xwiki:drafts.BMS Main 2\.1.configuration.WebHome1 +drafts.BMS Main 2\.1.3\. Configuration.WebHome - Content
-
... ... @@ -8,11 +8,10 @@ 8 8 9 9 (% id="cke_bm_2415S" style="display:none" %) (%%)To configure the input discrete and analog signals, select the menu "Signals → Input signals": 10 10 11 -[[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" height="290" width="272"]] 11 +[[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="272"]] 12 12 13 +**Discrete inputs** in this section: 13 13 14 -Discrete inputs in this section: 15 - 16 16 * No input; 17 17 * Battery cover – a signal from the battery cover trailer; 18 18 * Charger connected – a signal from the charger connector; ... ... @@ -29,24 +29,24 @@ 29 29 * CH/DCH contactor feedback – a feedback signal from the charging/discharging contactor; 30 30 * Main contactor feedback – a feedback signal from the main contactor. 31 31 32 -If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see section Battery cover31 +If the "Signal from the battery cover" assignment is selected, the discrete input is used to monitor the state of the battery cover (see [[Battery cover protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]). 33 33 34 -if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see sectionsCharge33 +if the "Charger connected" assignment is selected, the discrete input is involved in the algorithms of charge and discharge control (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 35 35 36 -If the "Power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see sectionsCharge35 +If the "Power up/down request" assignment is selected, the discrete input is involved in the algorithms of opening the charging and discharging relays and sending acknowledgment of power down to the external equipment (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 37 37 38 38 If the “Inhibit charging” assignment is selected, the discrete input is used to open the charging relay. 39 39 40 40 If the “Inhibit discharging” assignment is selected, the discrete input is used to open the discharging relay. 41 41 42 -If the “CH contactor feedback”, “DCH contactor feedback”, “PCH contactor feedback”, “CH/DCH contactor feedback” or “Main contactor feedback” assignment is selected, the discrete input is involved in monitoring the corresponding contactor’s feedback signal (see section Contactor41 +If the “CH contactor feedback”, “DCH contactor feedback”, “PCH contactor feedback”, “CH/DCH contactor feedback” or “Main contactor feedback” assignment is selected, the discrete input is involved in monitoring the corresponding contactor’s feedback signal (see [[Contactor feedback check>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HContactorfeedbackcheck"]]). 43 43 44 -If the “Charge request”, “Precharge request” or “Discharge request” assignment is selected, the discrete input is used to control opening the corresponding contactor (see sectionsCharge43 +If the “Charge request”, “Precharge request” or “Discharge request” assignment is selected, the discrete input is used to control opening the corresponding contactor (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 45 45 46 -If the “Insulation status” assignment is selected, the discrete input is used to monitor a signal from an external insulation monitoring device (see s ection Insulation45 +If the “Insulation status” assignment is selected, the discrete input is used to monitor a signal from an external insulation monitoring device (see [[Insulation monitoring>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HInsulationmonitoring"]]). 47 47 48 48 49 -Analog inputs in this section: 48 +**Analog inputs** in this section: 50 50 51 51 * No input; 52 52 * Current sensor; ... ... @@ -65,7 +65,7 @@ 65 65 66 66 (% class="box warningmessage" %) 67 67 ((( 68 -**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see section Series67 +**Important**: the connection of an additional current sensor (AUX) is possible for special hardware revision of the BMS Main 2.x board. Using an additional current sensor is possible in the configuration when BMS Main serves two galvanically isolated cell series (see [[Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 69 69 ))) 70 70 71 71 (% class="box warningmessage" %) ... ... @@ -84,7 +84,7 @@ 84 84 85 85 To configure the current sensor parameters, select the menu "Signals → Current sensor": 86 86 87 -[[image:1732202357233-620.png||data-xwiki-image-style-alignment="center" height="453" width="284"]] 86 +[[image:1732202357233-620.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="453" width="284"]] 88 88 89 89 In the «Primary sensor» и «Auxiliary sensor» sections: 90 90 ... ... @@ -114,7 +114,7 @@ 114 114 115 115 To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor": 116 116 117 -[[image:1732202640889-562.png||data-xwiki-image-style-alignment="center" height="342" width="265"]] 116 +[[image:1732202640889-562.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="342" width="265"]] 118 118 119 119 In this section: 120 120 ... ... @@ -136,7 +136,7 @@ 136 136 137 137 To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor": 138 138 139 -[[image:1732204766138-628.png||data-xwiki-image-style-alignment="center" height="112" width="256"]] 138 +[[image:1732204766138-628.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="256"]] 140 140 141 141 In this section: 142 142 ... ... @@ -152,7 +152,7 @@ 152 152 153 153 To set the humidity sensor parameters, select the menu "Signals → Humidity sensor": 154 154 155 -[[image:1732204899160-307.png||data-xwiki-image-style-alignment="center" height="120" width="195"]] 154 +[[image:1732204899160-307.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="195"]] 156 156 157 157 In this section: 158 158 ... ... @@ -168,9 +168,9 @@ 168 168 169 169 To configure output discrete signals and relays, select the menu "Signals → Output signals": 170 170 171 -[[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" height="346" width="295"]] 170 +[[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="346" width="295"]] 172 172 173 -Discrete outputs in this section: 172 +**Discrete outputs** in this section: 174 174 175 175 * No output; 176 176 * Low SOC; ... ... @@ -182,24 +182,24 @@ 182 182 * Acknowledgement of power down; 183 183 * Power up; 184 184 185 -If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see s ection Low184 +If the "Low SOC" assignment is selected, the output indicates the low battery charge level (see [[Low SOC signal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowSOCsignal"]]). 186 186 187 -If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see section High186 +If the "High battery charge current" assignment is selected, the output indicates that the charging current exceeds the predefined value (see [[High charging current signal>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHighchargingcurrentsignal"]]). 188 188 189 -If the "Cooler" assignment is selected, the output indicates the overheating of the battery (see sectionTemperature188 +If the "Cooler" assignment is selected, the output indicates the overheating of the battery (see [[High temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHightemperatureprotection"]]). 190 190 191 -If the "Heater" assignment is selected, the output indicates the low battery temperature signal (see section Temperature190 +If the "Heater" assignment is selected, the output indicates the low battery temperature signal (see [[Low temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowtemperatureprotection"]]). 192 192 193 -If the "Allow charging" assignment is selected, the output is used to give the charger the allowance to charge the battery (see section Charge192 +If the "Allow charging" assignment is selected, the output is used to give the charger the allowance to charge the battery (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 194 194 195 -If the "Precharging" assignment is selected, the output is used to charge the capacitive load (see section Discharge 194 +If the "Precharging" assignment is selected, the output is used to charge the capacitive load (see [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 196 196 197 -If the "Acknowledgement of power down" assignment is selected, the output is used to acknowledge power down of the BMS. Acknowledgement is outputted when the charge and discharge relays have been opened on power down request (see sectionsCharge196 +If the "Acknowledgement of power down" assignment is selected, the output is used to acknowledge power down of the BMS. Acknowledgement is outputted when the charge and discharge relays have been opened on power down request (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]] and [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 198 198 199 -If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see section Power198 +If the "Power up" assignment is selected, the output is used to indicate the power status of BMS (see [[Power down control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HPowerdowncontrol"]]). 200 200 201 201 202 -Relay assignments in this section: 201 +**Relay assignments** in this section: 203 203 204 204 * No relay; 205 205 * Charging; ... ... @@ -214,23 +214,23 @@ 214 214 * Main contactor; 215 215 * Power up. 216 216 217 -If the "Charging" assignment is selected, the relay is used to charge the battery (see section Charge216 +If the "Charging" assignment is selected, the relay is used to charge the battery (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 218 218 219 -If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see section Discharge 218 +If the "Discharging" assignment is selected, the relay is used to connect battery to the load (see [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 220 220 221 -If the "Allow charging" assignment is selected, the relay is used to give the charger an allowance to charge the battery (see section Charge220 +If the "Allow charging" assignment is selected, the relay is used to give the charger an allowance to charge the battery (see [[Charge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargecontrol"]]). 222 222 223 -If the "Cooler" assignment is selected, the relay receives a signal indicating overheating of the battery (see sectionTemperaturesection Cooler222 +If the "Cooler" assignment is selected, the relay receives a signal indicating overheating of the battery (see [[High temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHightemperatureprotection"]]) or the signal "Cooler" (see [[Cooler control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HCoolercontrol"]]). 224 224 225 -If the "Heater" assignment is selected, a low battery temperature signal is outputted to the relay (see sectionTemperaturesection Heater224 +If the "Heater" assignment is selected, a low battery temperature signal is outputted to the relay (see [[Low temperature protection>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HLowtemperatureprotection"]]) or a signal "Heater" (see [[Heater control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HHeatercontrol"]]). 226 226 227 -If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see section Discharge 226 +If the "Precharging" assignment is selected, the relay is used to charge the capacitive load (see [[Discharge control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargecontrol"]]). 228 228 229 -If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see section Series228 +If the "Balancing series 1" assignment is selected, the relay is used to connect a balancing resistor to the cell series 1 (see [[Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 230 230 231 -If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see section Series230 +If the "Balancing series 2" assignment is selected, the relay is used to connect a balancing resistor to the cell series 2 (see [[Series balancing>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.4 Battery parameters.WebHome||anchor="HSeriesbalancing"]]). 232 232 233 -If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see s ectionPoweringexternalquipment).232 +If the "Discharging (AUX)" assignment is selected, the relay is used to power external equipment (see [[Discharging (AUX) control>>doc:drafts.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischarging(AUX)control"]]). 234 234 235 235 If the "Main contactor" assignment is selected, the relay is used to close the main contactor in the common (minus) power bus. 236 236