Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,12 +4,11 @@ 4 4 5 5 BMS Main 2.x board has **4 analog inputs** for connecting current, temperature and humidity sensors. 6 6 7 -The order of the numbering of the discrete and analog inputs corresponds to the order of the numbering on the board. 8 - 9 9 (% id="cke_bm_2415S" style="display:none" %) (%%)To configure the input discrete and analog signals, select the menu "Signals → Input signals": 10 10 11 11 [[image:1732201986070-992.png||data-xwiki-image-style-alignment="center" height="290" width="272"]] 12 12 11 +The order of the numbering of the discrete and analog inputs corresponds to the order of the numbering on the board. 13 13 14 14 Discrete inputs in this section: 15 15 ... ... @@ -86,6 +86,7 @@ 86 86 87 87 [[image:1732202357233-620.png||data-xwiki-image-style-alignment="center" height="453" width="284"]] 88 88 88 + 89 89 In the «Primary sensor» и «Auxiliary sensor» sections: 90 90 91 91 * Sensor type – drop-down menu with supported sensor types; ... ... @@ -119,12 +119,12 @@ 119 119 In this section: 120 120 121 121 * Settings: 122 -* *Enable – a flag to start interaction with BMS Current Sensor (if interaction is enabled then BMS doesn’t use Hall-Effect current sensor which settings are described in the menu "Signals → Current sensor");123 -* *Node ID – an address of BMS Current Sensor in CANopen network;124 -* *Dispatch timeout – timeout of dispatching packages from BMS Current Sensor (if no data is being received from current sensor during this time, the “Shunt offline” flag is set), millisecond;125 -* *Zero level threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is lower than T,,0,,, BMS will assume that current flowing through the battery is zero);126 -* *Mean level threshold – TM level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is between T,,M,, and T,,0,,, BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, BMS will use instantaneous value of current I,,I,,);127 -* *Invert – a flag to invert current values;122 +* Enable – a flag to start interaction with BMS Current Sensor (if interaction is enabled then BMS doesn’t use Hall-Effect current sensor which settings are described in the menu "Signals → Current sensor"); 123 +* Node ID – an address of BMS Current Sensor in CANopen network; 124 +* Dispatch timeout – timeout of dispatching packages from BMS Current Sensor (if no data is being received from current sensor during this time, the “Shunt offline” flag is set), millisecond; 125 +* Zero level threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is lower than T,,0,,, BMS will assume that current flowing through the battery is zero); 126 +* Mean level threshold – TM level, A (if module of instantaneous current (I,,I,,) which is received from shunt sensor is between T,,M,, and T,,0,,, BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, BMS will use instantaneous value of current I,,I,,); 127 +* Invert – a flag to invert current values; 128 128 * Sensor state: 129 129 ** Online – a flag showing that the communication with the BMS Current Sensor is established; 130 130 ** Errors – a list of internal errors of the shunt sensor; ... ... @@ -138,6 +138,7 @@ 138 138 139 139 [[image:1732204766138-628.png||data-xwiki-image-style-alignment="center" height="112" width="256"]] 140 140 141 + 141 141 In this section: 142 142 143 143 * Type – type of temperature sensors. ... ... @@ -152,7 +152,7 @@ 152 152 153 153 To set the humidity sensor parameters, select the menu "Signals → Humidity sensor": 154 154 155 -[[image:1732204899160-307.png||data-xwiki-image-style-alignment="center" height="120" width="195"]] 156 +[[Humidity sensor settings>>image:1732204899160-307.png||data-xwiki-image-style-alignment="center" height="120" width="195"]] 156 156 157 157 In this section: 158 158 ... ... @@ -160,16 +160,17 @@ 160 160 161 161 == 3.3.6 Output signals == 162 162 163 -The BMS Main 2.x board has **4 discrete outputs**. For each discrete output, its purpose and inversion requirement are specified.164 +The BMS Main 2.x board has 4 discrete outputs. For each discrete output, its purpose and inversion requirement are specified. 164 164 165 -The BMS Main 2.x board has **4 solid-state relays**(#1 and #2 of them are bipolar, and the #3 and #4 are unipolar). For each relay, its purpose and inversion requirement are specified.166 +The BMS Main 2.x board has 4 solid-state relays (#1 and #2 of them are bipolar, and the #3 and #4 are unipolar). For each relay, its purpose and inversion requirement are specified. 166 166 167 -The order of the numbering of the discrete outputs and the relay corresponds to the order of the numbering on the board. 168 - 169 169 To configure output discrete signals and relays, select the menu "Signals → Output signals": 170 170 171 171 [[image:1732205046156-597.png||data-xwiki-image-style-alignment="center" height="346" width="295"]] 172 172 172 + 173 +The order of the numbering of the discrete outputs and the relay corresponds to the order of the numbering on the board. 174 + 173 173 Discrete outputs in this section: 174 174 175 175 * No output;
- 1732794334071-303.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -60.3 KB - Content