Changes for page 3.3 Input and output signals
Last modified by Admin on 2025/04/09 12:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -90,7 +90,7 @@ 90 90 ** Current sensor (AUX) – additional current sensor for measuring current in a series of cells; 91 91 ** Current zero level (AUX) – zero level bus for additional current sensor. 92 92 93 -== =3.3.2 Current sensor ===93 +== 3.3.2 Current sensor == 94 94 95 95 After selecting the assignment of the analog inputs, you need to configure the parameters of the sensors connected to the board. 96 96 ... ... @@ -123,7 +123,7 @@ 123 123 124 124 Calibration of the current sensor (“Calibrate sensor on startup” flag) is necessary if the sensor does not have a reference line (zero level signal). 125 125 126 -== =3.3.3 Current shunt sensor ===126 +== 3.3.3 Current shunt sensor == 127 127 128 128 To configure the shunt current sensor parameters, select the menu "Signals → Current shunt sensor": 129 129 ... ... @@ -145,7 +145,7 @@ 145 145 ** Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); 146 146 ** Temperature – a temperature of the shunt sensor, °C. 147 147 148 -== =3.3.4 Temperature sensor ===148 +== 3.3.4 Temperature sensor == 149 149 150 150 To configure the temperature sensor parameters, select the menu "Signals → Temperature sensor": 151 151 ... ... @@ -162,7 +162,7 @@ 162 162 **Note:** Temperature sensors connected to the BMS Main 2.x and BMS Logic boards must be the same type. 163 163 ))) 164 164 165 -== =3.3.5 Humidity sensor ===165 +== 3.3.5 Humidity sensor == 166 166 167 167 To set the humidity sensor parameters, select the menu "Signals → Humidity sensor": 168 168 ... ... @@ -172,7 +172,7 @@ 172 172 173 173 * Type – type of the humidity sensor. 174 174 175 -== =3.3.6 Output signals ===175 +== 3.3.6 Output signals == 176 176 177 177 The BMS Main 2.x board has 4 discrete outputs. For each discrete output, its purpose and inversion requirement are specified. The following discrete output assignment options are supported: 178 178 ... ... @@ -242,4 +242,33 @@ 242 242 243 243 To configure output discrete signals and relays, select the menu "Signals → Output signals": 244 244 245 -[[Output >>image:1732205046156-597.png||data-xwiki-image-style-alignment="center" height="346" width="295"]] 245 +[[Output signals section>>image:1732205046156-597.png||data-xwiki-image-style-alignment="center" height="346" width="295"]] 246 + 247 + 248 +The order of the numbering of the discrete outputs and the relay corresponds to the order of the numbering on the board. 249 + 250 +In this section: 251 + 252 +* Discrete outputs: 253 +** No output; 254 +** Low SOC; 255 +** High charging current; 256 +** Cooler; 257 +** Heater; 258 +** Allow charging; 259 +** Precharging; 260 +** Acknowledgement of power down; 261 +** Power up; 262 +* Relay: 263 +** No relay; 264 +** Charging; 265 +** Discharging; 266 +** Allow charging; 267 +** Cooler; 268 +** Heater; 269 +** Precharging; 270 +** Balancing series 1; 271 +** Balancing series 2; 272 +** Discharging (AUX); 273 +** Main contactor; 274 +** Power up.