2 = Installation and connection =
Admin 25.4 3
Admin 49.1 4 == Installation procedure ==
5
Admin 45.1 6 Overall and mounting dimensions of the BMS Main 2.1 are shown below.
Admin 26.2 7
Admin 44.1 8 [[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]]
Admin 26.2 9
Admin 49.3 10 (% style="width:494px" %)
11 |**Parameter**|(% style="width:178px" %)**Value**
12 |Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32
13 |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114
14 |Mounting holes|(% style="width:178px" %)M3
Admin 26.2 15
Admin 49.1 16 == Connection procedure ==
Admin 26.2 17
Admin 20.3 18 The mounting area of the BMS Main 2.1 must be protected from mechanical particles (dust, dirt, large objects) and water. The installation site must provide convenient access for subsequent connection to the device’s headers.
Admin 1.2 19
Admin 20.3 20 1. Connect the charging and discharging contactors to the P6-P9 headers.
21 1. Connect a current sensor to the P12 header according to its documentation. The positive current direction (indicated by an arrow on the sensor) corresponds to the battery charging. It is recommended to use a shielded cable to connect the current sensor, the shield should be grounded on the side of the current sensor. The cable should be positioned as far as possible from the high current circuits. If the current sensor has a reference voltage line, connect it to pin 4 of the P12 header.
22 1. Connect the BMS Main 2.1 to the on-board CAN network. Observe the rules for connecting CAN devices. If the BMS Main 2.1 is the last device on a bus, close pins 1-2 on the P21 jumper, otherwise leave the jumper on pins 2-3.
23 1. Connect a power supply to the P1 header. It is not recommended to power the BMS Main 2.1 from the battery only, since at a critical discharge of the battery, it is not possible to turn on the BMS and close the charging contactor.
24
Admin 49.1 25 == ​​​​Headers description ==
Admin 20.3 26
Admin 1.2 27 The BMS Main 2.1 headers are shown in figure below.
28
Admin 44.1 29 [[image:1731516393377-928.jpeg||alt="1731517946345-632.png" data-xwiki-image-style-alignment="center" height="417" width="451"]]
Admin 1.2 30
Admin 48.1 31 (% class="box warningmessage" %)
32 (((
33 **Attention!**
34 All headers are shown from the device side!
35 )))
Admin 20.3 36
Admin 49.1 37 === P1 – header for power supply ===
Admin 2.2 38
Admin 55.1 39 Receptacle Housing: Molex 39012020. Terminals: Molex 5556
40
Admin 47.1 41 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
Admin 2.2 42
Admin 46.1 43 |**Pin**|**Name**|**Description**
44 |**1**|**GND**|Ground
45 |**2**|**V+**|Supply voltage 9-30V
Admin 4.2 46
Admin 49.1 47 === P15 – header for BMS Logic ===
Admin 4.2 48
Admin 55.1 49 Receptacle Housing: Molex 430250400. Terminals: Molex 43030
50
Admin 47.1 51 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
Admin 4.2 52
Admin 46.1 53 |**Pin**|**Name**|**Description**
54 |**1**|**RS485_A**|RS-485 line A for communication with BMS Logic
55 |**2**|**RS485_B**|RS-485 line B for communication with BMS Logic
56 |**3**|**+5V**|Supply voltage for BMS Logic
57 |**4**|**GND**|Ground
Admin 44.1 58
Admin 49.1 59 === P12 – header for current sensor ===
Admin 5.2 60
Admin 55.1 61 Receptacle Housing: Molex 430250400. Terminals: Molex 43030
62
Admin 47.1 63 [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
Admin 5.3 64
Admin 46.1 65 |**Pin**|**Name**|**Description**
66 |**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA
67 |**2**|**GND**|Ground
68 |**3**|**Vcs**|ADC input (current sensor output)
69 |**4**|**Vref**|ADC input (current sensor reference signal)
Admin 5.3 70
Admin 49.1 71 === P13 – header for humidity sensor ===
Admin 5.3 72
Admin 55.1 73 Receptacle Housing: Molex 430250400. Terminals: Molex 43030
74
Admin 47.1 75 [[image:1732198896526-660.png||data-xwiki-image-style-alignment="center" height="70" width="64"]]
Admin 6.2 76
Admin 46.1 77 |**Pin**|**Name**|**Description**
78 |**1**|**+5V**|Supply voltage 5 V, max 50 mA
79 |**2**|**GND**|Ground
80 |**3**|**Vhs**|ADC input (humidity sensor output)
81 |**4**|**Vts**|ADC input (temperature sensor output)
Admin 6.2 82
Admin 49.1 83 === P8 – header of relay 1 ===
Admin 6.2 84
Admin 55.1 85 Receptacle Housing: Molex 39012020. Terminals: Molex 5556
86
Admin 47.1 87 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
Admin 6.2 88
89 By default, relay 1 is used to control the discharging contactor.
90
Admin 46.1 91 |**Pin**|**Name**|**Description**
92 |**1**|**V+**|Switching voltage (up to 55V, max 2A)
93 |**2**|**NO**|Normally open contact
Admin 6.2 94
Admin 49.1 95 === P9 – header of relay 2 ===
Admin 11.2 96
Admin 55.1 97 Receptacle Housing: Molex 39012020. Terminals: Molex 5556
98
Admin 47.1 99 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
Admin 11.2 100
101 By default, relay 2 is used to output the “Allow charging” signal.
102
Admin 46.1 103 |**Pin**|**Name**|**Description**
104 |**1**|**V+**|Switching voltage (up to 55V, max 2A)
105 |**2**|**NO**|Normally open contact
Admin 6.2 106
Admin 49.1 107 === P6 – header of relay 3 ===
Admin 6.2 108
Admin 55.1 109 Receptacle Housing: Molex 39012020. Terminals: Molex 5556
110
Admin 47.1 111 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
Admin 6.2 112
Admin 11.2 113 By default, relay 3 is used to control the charging contactor.
Admin 6.2 114
Admin 46.1 115 |**Pin**|**Name**|**Description**
116 |**1**|**V+**|Switching voltage (up to 55V, max 8A)
117 |**2**|**NO**|Normally open contact
Admin 6.2 118
Admin 49.1 119 === P7 – header of relay 4 ===
Admin 6.2 120
Admin 55.1 121 Receptacle Housing: Molex 39012020. Terminals: Molex 5556
122
Admin 47.1 123 [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
Admin 11.2 124
125 By default, relay 4 is used to control the heater.
126
Admin 46.1 127 |**Pin**|**Name**|**Description**
128 |**1**|**V+**|Switching voltage (up to 55V, max 8A)
129 |**2**|**NO**|Normally open contact
Admin 6.2 130
Admin 49.1 131 === P14 – header for CAN and RS-485 interfaces ===
Admin 6.2 132
Admin 55.1 133 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
134
Admin 47.1 135 [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center" height="81" width="113"]]
Admin 6.2 136
Admin 21.3 137 (% style="width:641px" %)
Admin 46.1 138 |**Pin**|**Name**|**Description**
139 |**1**|**EXT_RS485_A**|RS-485 line A for communication with external equipment
140 |**2**|**CAN_H**|CAN H line for communication with external equipment
141 |**3**|**+5V_CAN**|Supply voltage 5V for external devices, max 200 mA
142 |**4**|**EXT_RS485_B**|RS-485 line B for communication with external equipment
143 |**5**|**CAN_L**|CAN L line for communication with external equipment
144 |**6**|**GND_CAN**|Ground
Admin 11.2 145
Admin 49.1 146 === P21 – CAN termination resistor jumper ===
Admin 11.2 147
Admin 47.1 148 [[image:1731517188900-976.png||data-xwiki-image-style-alignment="center" height="78" width="149"]]
Admin 11.2 149
150 To connect the termination resistor between the lines **CAN_H** and **CAN_L**, install a jumper, according to the P21 pinout:
151
Admin 46.1 152 |**Pin**|**Name**|**Description**
153 |**1-2**|**120 Ohm**|Termination resistor 120 Ohm is connected
154 |**2-3**|**-**|Termination resistor 120 Ohm is not connected
Admin 11.2 155
Admin 49.1 156 === P22 - RS-485 termination resistor jumper ===
Admin 11.2 157
Admin 47.1 158 [[image:1731517195672-298.png||data-xwiki-image-style-alignment="center" height="81" width="155"]]
Admin 11.2 159
160 To connect the termination resistor between the **EXT_RS485_A** and **EXT_RS485_B** lines, install a jumper according to the P22 pinout:
161
Admin 46.1 162 |**Pin**|**Name**|**Description**
163 |**1-2**|**120 Ohm**|Terminating resistor 120 Ohm is connected
164 |**2-3**|**-**|Terminating resistor 120 Ohm is not connected
Admin 11.2 165
Admin 49.1 166 === P11 – header for discrete inputs/outputs ===
Admin 11.2 167
Admin 55.1 168 Receptacle Housing: Molex 430251600. Terminals: Molex 43030
169
Admin 47.1 170 [[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]]
Admin 11.2 171
Admin 46.1 172 |**Pin**|**Name**|**Description**
173 |**16**|**IN_1**|Discrete input #1 “dry contact” (+5V)
174 |**8**|**GND_1**|Discrete input #1 “dry contact” (ground)
175 |**15**|**IN_2**|Discrete input #2 “dry contact” (+5V)
176 |**7**|**GND_2**|Discrete input #2 “dry contact” (ground)
177 |**14**|**IN_3**|Discrete input #3 “dry contact” (+5V)
178 |**6**|**GND_3**|Discrete input #3 “dry contact” (ground)
179 |**13**|**IN_4**|Discrete input #4 “dry contact” (+5V)
180 |**5**|**GND_4**|Discrete input #4 “dry contact” (ground)
181 |**12**|**OUT_4**|Discrete output #4 (+5V, 20mA)
182 |**4**|**GND_OUT_4**|Discrete output #4 (ground)
183 |**11**|**OUT_3**|Discrete output #3 (+5V, 20mA)
184 |**3**|**GND_OUT_3**|Discrete output #3 (ground)
185 |**10**|**OUT_2**|Discrete output #2 (+5V, 20mA)
186 |**2**|**GND_OUT_2**|Discrete output #2 (ground)
187 |**9**|**OUT_1**|Discrete output #1 (+5V, 20mA)
188 |**1**|**GND_OUT_1**|Discrete output #1 (ground)
Admin 11.2 189
Admin 49.1 190 == Indicators ==
Admin 11.2 191
Admin 49.1 192 === DS1 – power indicator ===
Admin 13.1 193
Admin 46.1 194 |**State**|**Description**
195 |**Lights red**|The device is powered
196 |**Off**|The device is not powered
Admin 11.2 197
Admin 49.1 198 === DS2 – operation indicator ===
Admin 11.2 199
Admin 46.1 200 |**State**|**Description**
201 |**Blinking green**|The BMS firmware is running
202 |**Off**|The BMS firmware is not running
Admin 11.2 203
Admin 49.1 204 === DS3 – communication indicator ===
Admin 11.2 205
Admin 46.1 206 |**State**|**Description**
207 |**Blinking yellow (2Hz)**|Initializing communication with BMS Logic boards
208 |**Blinking yellow (25Hz)**|Communication with BMS Logic is established
Admin 11.2 209
Admin 49.1 210 === DS4 – error indicator ===
Admin 11.2 211
212
Admin 46.1 213 |(**State**|**Description**
214 |(**Blinking red**|Errors in communication with BMS Logic
215
Admin 49.1 216 === DS7 – relay 1 indicator ===
Admin 11.2 217
Admin 46.1 218 |**State**|**Description**
219 |**Lights green**|Relay #1 is closed
220 |**Off**|Relay #1 is opened
Admin 11.2 221
Admin 49.1 222 === DS8 – relay 2 indicator ===
Admin 11.2 223
Admin 46.1 224 |**State**|**Description**
225 |**Lights green**|Relay #2 is closed
226 |**Off**|Relay #2 is opened
Admin 19.1 227
Admin 49.1 228 === DS5 – relay 3 indicator ===
Admin 11.2 229
Admin 46.1 230 |**State**|**Description**
231 |**Lights green**|Relay #3 is closed
232 |**Off**|Relay #3 is opened
Admin 11.2 233
Admin 49.1 234 === DS6 – relay 4 indicator ===
Admin 11.2 235
Admin 46.1 236 |**State**|**Description**
237 |**Lights green**|Relay #4 is closed
238 |**Off**|Relay #4 is opened
Admin 11.2 239