Wiki source code of 2. Connection

Version 10.1 by Admin on 2024/11/13 16:59

Hide last authors
Admin 1.2 1 = ​​​​Headers =
2
3 The BMS Main 2.1 headers are shown in figure below.
4
5 [[The BMS Main 2.1 headers>>image:1731516393377-928.jpeg||height="430" width="428"]]
6
Admin 2.2 7 == P1 – header for power supply ==
8
Admin 4.2 9 [[image:1731516593096-166.png||data-xwiki-image-style-alignment="center" height="93" width="49"]]
Admin 2.2 10
11 |**Pin**|**Name**|**Description**
12 |**1**|**GND**|Ground
13 |**2**|**V+**|Supply voltage 9-30V
Admin 4.2 14
15 == P15 – header for BMS Logic ==
16
17 [[image:1731516577472-301.png||data-xwiki-image-style-alignment="center" height="90" width="83"]]
18
Admin 5.2 19 |**Pin**|**Name**|**Description**
20 |**1**|**RS485_A**|RS-485 line A for communication with BMS Logic
Admin 4.2 21 |**2**|**RS485_B**|RS-485 line B for communication with BMS Logic
22 |**3**|**+5V**|Supply voltage for BMS Logic
23 |**4**|**GND**|Ground
Admin 5.2 24
25 == P12 – header for current sensor ==
26
Admin 5.3 27 [[image:1731516685999-633.png||data-xwiki-image-style-alignment="center" height="98" width="90"]]
28
29 |**Pin**|**Name**|**Description**
30 |**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA
31 |**2**|**GND**|Ground
32 |**3**|**Vcs**|ADC input (current sensor output)
33 |**4**|**Vref**|ADC input (current sensor reference signal)
34
Admin 6.2 35 == P13 – header for humidity sensor ==
Admin 5.3 36
Admin 6.2 37 [[image:1731516942455-641.png||data-xwiki-image-style-alignment="center"]]
38
39 |**Pin**|**Name**|**Description**
40 |**1**|**+5V**|Supply voltage 5 V, max 50 mA
41 |**2**|**GND**|Ground
42 |**3**|**Vhs**|ADC input (humidity sensor output)
43 |**4**|**Vts**|ADC input (temperature sensor output)
44
45
46 1.
47 11.
48 111. P8 – header of relay 1
49
50 [[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]]
51
52 By default, relay 1 is used to control the discharging contactor.
53
54
55 |**Pin**|**Name**|**Description**
56 |**1**|**V+**|Switching voltage (up to 55V, max 2A)
57 |**2**|**NO**|Normally open contact
58
59
60 1.
61 11.
62 111. P9 – header of relay 2
63
64 [[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]]
65
66 By default, relay 2 is used to output the “Allow charging” signal.
67
68
69 |**Pin**|**Name**|**Description**
70 |**1**|**V+**|Switching voltage (up to 55V, max 2A)
71 |**2**|**NO**|Normally open contact
72