Details
- Page properties
-
- Content
-
... ... @@ -3,11 +3,11 @@ 3 3 4 4 == Safety rules == 5 5 6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor**able to break the load and charge circuits must be connected to the BMS.6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 7 8 8 Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 9 10 -(% class="box errormessage" %)10 +(% class="box warningmessage" %) 11 11 ((( 12 12 The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 13 ))) ... ... @@ -14,7 +14,7 @@ 14 14 15 15 (% class="box errormessage" %) 16 16 ((( 17 -The system is not designed to operate with batteries whose total voltage exceeds 1200 V. 17 +**The system is not designed to operate with batteries whose total voltage exceeds 1200 V.** 18 18 ))) 19 19 20 20 == Installation procedure == ... ... @@ -21,11 +21,11 @@ 21 21 22 22 Overall and mounting dimensions of the BMS Main 2.1 are shown below. 23 23 24 -[[image:17 52600650898-961.png||data-xwiki-image-style-alignment="center" height="546" width="450"]]24 +[[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]] 25 25 26 26 (% style="width:494px" %) 27 27 |**Parameter**|(% style="width:178px" %)**Value** 28 -|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 1728 +|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32 29 29 |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114 30 30 |Mounting holes|(% style="width:178px" %)M3 31 31 ... ... @@ -81,8 +81,8 @@ 81 81 |**Pin**|**Name**|**Description** 82 82 |**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 83 83 |**2**|**GND**|Ground 84 -|**3**|**Vcs**|ADC input 1(current sensor output)85 -|**4**|**Vref**|ADC input 2(current sensor reference signal)84 +|**3**|**Vcs**|ADC input (current sensor output) 85 +|**4**|**Vref**|ADC input (current sensor reference signal) 86 86 87 87 === P13 – header for humidity sensor === 88 88 ... ... @@ -93,8 +93,8 @@ 93 93 |**Pin**|**Name**|**Description** 94 94 |**1**|**+5V**|Supply voltage 5 V, max 50 mA 95 95 |**2**|**GND**|Ground 96 -|**3**|**V ts**|ADC input3(temperaturesensor output)97 -|**4**|**V hs**|ADC input4(humiditysensor output)96 +|**3**|**Vhs**|ADC input (humidity sensor output) 97 +|**4**|**Vts**|ADC input (temperature sensor output) 98 98 99 99 === P8 – header of relay 1 === 100 100
- 1752600650898-961.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -84.9 KB - Content
- 1752600811993-973.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -84.9 KB - Content