Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,30 +1,15 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 -== Safety rules == 5 - 6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS. 7 - 8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 - 10 -(% class="box errormessage" %) 11 -((( 12 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 -))) 14 - 15 -(% class="box errormessage" %) 16 -((( 17 -The system is not designed to operate with batteries whose total voltage exceeds 1200 V. 18 -))) 19 - 20 20 == Installation procedure == 21 21 22 22 Overall and mounting dimensions of the BMS Main 2.1 are shown below. 23 23 8 +[[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]] 24 24 25 25 (% style="width:494px" %) 26 26 |**Parameter**|(% style="width:178px" %)**Value** 27 -|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 1712 +|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32 28 28 |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114 29 29 |Mounting holes|(% style="width:178px" %)M3 30 30 ... ... @@ -107,9 +107,9 @@ 107 107 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 108 108 |**2**|**NO**|Normally open contact 109 109 110 -Contactor connection example for all relays:95 +Contactor connection example: 111 111 112 -[[image:1741619 814065-850.png||height="189" width="252"]]97 +[[image:1741619700532-367.png||height="184" width="246"]] 113 113 114 114 === P9 – header of relay 2 === 115 115 ... ... @@ -123,8 +123,6 @@ 123 123 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 124 124 |**2**|**NO**|Normally open contact 125 125 126 -Contactor connection example: see relay 1. 127 - 128 128 === P6 – header of relay 3 === 129 129 130 130 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -138,8 +138,6 @@ 138 138 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 139 139 |**2**|**NO**|Normally open contact 140 140 141 -Contactor connection example: see relay 1. 142 - 143 143 === P7 – header of relay 4 === 144 144 145 145 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -153,8 +153,6 @@ 153 153 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 154 154 |**2**|**NO**|Normally open contact 155 155 156 -Contactor connection example: see relay 1. 157 - 158 158 === P14 – header for CAN and RS-485 interfaces === 159 159 160 160 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.3 KB - Content
- 1752600650898-961.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -84.9 KB - Content