... ... @@ -1,22 +1,6 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 -== Safety rules ==
5 -
6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS.
7 -
8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 -
10 -(% class="box errormessage" %)
11 -(((
12 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 -)))
14 -
15 -(% class="box errormessage" %)
16 -(((
17 -The system is not designed to operate with batteries whose total voltage exceeds 1200 V.
18 -)))
19 -
20 20  == Installation procedure ==
21 21  
22 22  Overall and mounting dimensions of the BMS Main 2.1 are shown below.
... ... @@ -108,10 +108,8 @@
108 108  |**1**|**V+**|Switching voltage (up to 55V, max 3A)
109 109  |**2**|**NO**|Normally open contact
110 110  
111 -Contactor connection example for all relays:
95 +Contactor
112 112  
113 -[[image:1741619814065-850.png||height="189" width="252"]]
114 -
115 115  === P9 – header of relay 2 ===
116 116  
117 117  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
... ... @@ -124,8 +124,6 @@
124 124  |**1**|**V+**|Switching voltage (up to 55V, max 3A)
125 125  |**2**|**NO**|Normally open contact
126 126  
127 -Contactor connection example: see relay 1.
128 -
129 129  === P6 – header of relay 3 ===
130 130  
131 131  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
... ... @@ -139,8 +139,6 @@
139 139  up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
140 140  |**2**|**NO**|Normally open contact
141 141  
142 -Contactor connection example: see relay 1.
143 -
144 144  === P7 – header of relay 4 ===
145 145  
146 146  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
... ... @@ -154,8 +154,6 @@
154 154  up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
155 155  |**2**|**NO**|Normally open contact
156 156  
157 -Contactor connection example: see relay 1.
158 -
159 159  === P14 – header for CAN and RS-485 interfaces ===
160 160  
161 161  Receptacle Housing: Molex 430250600. Terminals: Molex 43030
1741619700532-367.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -14.1 KB
Content
1741619814065-850.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -15.1 KB
Content
1741620022836-867.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -13.3 KB
Content