Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,22 +1,6 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 -== Safety rules == 5 - 6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS. 7 - 8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 - 10 -(% class="box warningmessage" %) 11 -((( 12 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 -))) 14 - 15 -(% class="box errormessage" %) 16 -((( 17 -**The system is not designed to operate with batteries whose total voltage exceeds 1200 V.** 18 -))) 19 - 20 20 == Installation procedure == 21 21 22 22 Overall and mounting dimensions of the BMS Main 2.1 are shown below. ... ... @@ -108,10 +108,8 @@ 108 108 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 109 109 |**2**|**NO**|Normally open contact 110 110 111 -Contactor connection example for all relays:95 +Contactor 112 112 113 -[[image:1741619814065-850.png||height="189" width="252"]] 114 - 115 115 === P9 – header of relay 2 === 116 116 117 117 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -124,8 +124,6 @@ 124 124 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 125 125 |**2**|**NO**|Normally open contact 126 126 127 -Contactor connection example: see relay 1. 128 - 129 129 === P6 – header of relay 3 === 130 130 131 131 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -139,8 +139,6 @@ 139 139 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 140 140 |**2**|**NO**|Normally open contact 141 141 142 -Contactor connection example: see relay 1. 143 - 144 144 === P7 – header of relay 4 === 145 145 146 146 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -154,8 +154,6 @@ 154 154 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 155 155 |**2**|**NO**|Normally open contact 156 156 157 -Contactor connection example: see relay 1. 158 - 159 159 === P14 – header for CAN and RS-485 interfaces === 160 160 161 161 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
- 1741619700532-367.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.1 KB - Content
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.1 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.3 KB - Content