Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,22 +1,6 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 -== Safety rules == 5 - 6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 - 8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 - 10 -(% class="box warningmessage" %) 11 -((( 12 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 -))) 14 - 15 -(% class="box errormessage" %) 16 -((( 17 -**The system is not designed to operate with batteries whose total voltage exceeds 1200 V.** 18 -))) 19 - 20 20 == Installation procedure == 21 21 22 22 Overall and mounting dimensions of the BMS Main 2.1 are shown below. ... ... @@ -108,10 +108,6 @@ 108 108 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 109 109 |**2**|**NO**|Normally open contact 110 110 111 -Contactor connection example for all relays: 112 - 113 -[[image:1741619814065-850.png||height="189" width="252"]] 114 - 115 115 === P9 – header of relay 2 === 116 116 117 117 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -124,8 +124,6 @@ 124 124 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 125 125 |**2**|**NO**|Normally open contact 126 126 127 -Contactor connection example: see relay 1. 128 - 129 129 === P6 – header of relay 3 === 130 130 131 131 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -139,8 +139,6 @@ 139 139 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 140 140 |**2**|**NO**|Normally open contact 141 141 142 -Contactor connection example: see relay 1. 143 - 144 144 === P7 – header of relay 4 === 145 145 146 146 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -154,8 +154,6 @@ 154 154 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 155 155 |**2**|**NO**|Normally open contact 156 156 157 -Contactor connection example: see relay 1. 158 - 159 159 === P14 – header for CAN and RS-485 interfaces === 160 160 161 161 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
- 1741619700532-367.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.1 KB - Content
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.1 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.3 KB - Content