Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,24 +1,6 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 -== Safety rules == 5 - 6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 - 8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 - 10 -It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 11 - 12 -(% class="box warningmessage" %) 13 -((( 14 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 15 -))) 16 - 17 -(% class="box errormessage" %) 18 -((( 19 -**The system is not designed to operate with batteries whose total voltage exceeds 1200 V.** 20 -))) 21 - 22 22 == Installation procedure == 23 23 24 24 Overall and mounting dimensions of the BMS Main 2.1 are shown below. ... ... @@ -110,10 +110,6 @@ 110 110 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 111 111 |**2**|**NO**|Normally open contact 112 112 113 -Contactor connection example for all relays: 114 - 115 -[[image:1741619814065-850.png||height="189" width="252"]] 116 - 117 117 === P9 – header of relay 2 === 118 118 119 119 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -126,8 +126,6 @@ 126 126 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 127 127 |**2**|**NO**|Normally open contact 128 128 129 -Contactor connection example: see relay 1. 130 - 131 131 === P6 – header of relay 3 === 132 132 133 133 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -141,8 +141,6 @@ 141 141 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 142 142 |**2**|**NO**|Normally open contact 143 143 144 -Contactor connection example: see relay 1. 145 - 146 146 === P7 – header of relay 4 === 147 147 148 148 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -156,8 +156,6 @@ 156 156 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 157 157 |**2**|**NO**|Normally open contact 158 158 159 -Contactor connection example: see relay 1. 160 - 161 161 === P14 – header for CAN and RS-485 interfaces === 162 162 163 163 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
- 1741619700532-367.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.1 KB - Content
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.1 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.3 KB - Content