Last modified by Admin on 2025/07/15 17:33

From version 63.1
edited by Admin
on 2025/03/18 12:17
Change comment: There is no comment for this version
To version 53.1
edited by Admin
on 2025/02/06 11:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,24 +1,6 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 -== Safety rules ==
5 -
6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS.
7 -
8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 -
10 -It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series.
11 -
12 -(% class="box warningmessage" %)
13 -(((
14 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
15 -)))
16 -
17 -(% class="box errormessage" %)
18 -(((
19 -**The system is not designed to operate with batteries whose total voltage exceeds 1200 V.**
20 -)))
21 -
22 22  == Installation procedure ==
23 23  
24 24  Overall and mounting dimensions of the BMS Main 2.1 are shown below.
... ... @@ -30,6 +30,8 @@
30 30  |Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32
31 31  |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114
32 32  |Mounting holes|(% style="width:178px" %)M3
15 +|Headers type P1, P6-P9|(% style="width:178px" %)Molex series Mini-Fit
16 +|Headers type P11-P15|(% style="width:178px" %)Molex series Micro-Fit
33 33  
34 34  == Connection procedure ==
35 35  
... ... @@ -54,8 +54,6 @@
54 54  
55 55  === P1 – header for power supply ===
56 56  
57 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556
58 -
59 59  [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
60 60  
61 61  |**Pin**|**Name**|**Description**
... ... @@ -64,8 +64,6 @@
64 64  
65 65  === P15 – header for BMS Logic ===
66 66  
67 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
68 -
69 69  [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
70 70  
71 71  |**Pin**|**Name**|**Description**
... ... @@ -76,8 +76,6 @@
76 76  
77 77  === P12 – header for current sensor ===
78 78  
79 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
80 -
81 81  [[image:1732198890482-787.png||data-xwiki-image-style-alignment="center" height="77" width="71"]]
82 82  
83 83  |**Pin**|**Name**|**Description**
... ... @@ -88,8 +88,6 @@
88 88  
89 89  === P13 – header for humidity sensor ===
90 90  
91 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
92 -
93 93  [[image:1732198896526-660.png||data-xwiki-image-style-alignment="center" height="70" width="64"]]
94 94  
95 95  |**Pin**|**Name**|**Description**
... ... @@ -100,68 +100,46 @@
100 100  
101 101  === P8 – header of relay 1 ===
102 102  
103 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556
104 -
105 105  [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
106 106  
107 107  By default, relay 1 is used to control the discharging contactor.
108 108  
109 109  |**Pin**|**Name**|**Description**
110 -|**1**|**V+**|Switching voltage (up to 55V, max 3A)
84 +|**1**|**V+**|Switching voltage (up to 55V, max 2A)
111 111  |**2**|**NO**|Normally open contact
112 112  
113 -Contactor connection example for all relays:
114 -
115 -[[image:1741619814065-850.png||height="189" width="252"]]
116 -
117 117  === P9 – header of relay 2 ===
118 118  
119 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556
120 -
121 121  [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
122 122  
123 123  By default, relay 2 is used to output the “Allow charging” signal.
124 124  
125 125  |**Pin**|**Name**|**Description**
126 -|**1**|**V+**|Switching voltage (up to 55V, max 3A)
94 +|**1**|**V+**|Switching voltage (up to 55V, max 2A)
127 127  |**2**|**NO**|Normally open contact
128 128  
129 -Contactor connection example: see relay 1.
130 -
131 131  === P6 – header of relay 3 ===
132 132  
133 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556
134 -
135 135  [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
136 136  
137 137  By default, relay 3 is used to control the charging contactor.
138 138  
139 139  |**Pin**|**Name**|**Description**
140 -|**1**|**V+**|Switching voltage up to 55V,
141 -up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
104 +|**1**|**V+**|Switching voltage (up to 55V, max 8A)
142 142  |**2**|**NO**|Normally open contact
143 143  
144 -Contactor connection example: see relay 1.
145 -
146 146  === P7 – header of relay 4 ===
147 147  
148 -Receptacle Housing: Molex 39012020. Terminals: Molex 5556
149 -
150 150  [[image:1732198827034-560.png||data-xwiki-image-style-alignment="center" height="78" width="41"]]
151 151  
152 152  By default, relay 4 is used to control the heater.
153 153  
154 154  |**Pin**|**Name**|**Description**
155 -|**1**|**V+**|Switching voltage up to 55V,
156 -up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
114 +|**1**|**V+**|Switching voltage (up to 55V, max 8A)
157 157  |**2**|**NO**|Normally open contact
158 158  
159 -Contactor connection example: see relay 1.
160 -
161 161  === P14 – header for CAN and RS-485 interfaces ===
162 162  
163 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030
164 -
165 165  [[image:1731517180930-597.png||data-xwiki-image-style-alignment="center" height="81" width="113"]]
166 166  
167 167  (% style="width:641px" %)
... ... @@ -195,8 +195,6 @@
195 195  
196 196  === P11 – header for discrete inputs/outputs ===
197 197  
198 -Receptacle Housing: Molex 430251600. Terminals: Molex 43030
199 -
200 200  [[image:1732198937514-731.png||data-xwiki-image-style-alignment="center" height="85" width="272"]]
201 201  
202 202  |**Pin**|**Name**|**Description**
1741619628288-759.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -29.2 KB
Content
1741619637854-961.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -29.2 KB
Content
1741619700532-367.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -14.1 KB
Content
1741619814065-850.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -15.1 KB
Content
1741620022836-867.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -13.3 KB
Content