Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,60 +16,7 @@ 16 16 17 17 [[image:1731516577472-301.png||data-xwiki-image-style-alignment="center" height="90" width="83"]] 18 18 19 -|**Pin**|**Name**|**Description** 20 -|**1**|**RS485_A**|RS-485 line A for communication with BMS Logic 19 +|**1**|**RS485_A**|**RS-485 line A for communication with BMS Logic** 21 21 |**2**|**RS485_B**|RS-485 line B for communication with BMS Logic 22 22 |**3**|**+5V**|Supply voltage for BMS Logic 23 23 |**4**|**GND**|Ground 24 - 25 -== P12 – header for current sensor == 26 - 27 -[[image:1731516685999-633.png||data-xwiki-image-style-alignment="center" height="98" width="90"]] 28 - 29 -|**Pin**|**Name**|**Description** 30 -|**1**|**+5V**|Supply voltage for the current sensor 5V, max 50 mA 31 -|**2**|**GND**|Ground 32 -|**3**|**Vcs**|ADC input (current sensor output) 33 -|**4**|**Vref**|ADC input (current sensor reference signal) 34 - 35 -== P13 – header for humidity sensor == 36 - 37 -[[image:1731516942455-641.png||data-xwiki-image-style-alignment="center"]] 38 - 39 -|**Pin**|**Name**|**Description** 40 -|**1**|**+5V**|Supply voltage 5 V, max 50 mA 41 -|**2**|**GND**|Ground 42 -|**3**|**Vhs**|ADC input (humidity sensor output) 43 -|**4**|**Vts**|ADC input (temperature sensor output) 44 - 45 - 46 -1. 47 -11. 48 -111. P8 – header of relay 1 49 - 50 -[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]] 51 - 52 -By default, relay 1 is used to control the discharging contactor. 53 - 54 - 55 -|**Pin**|**Name**|**Description** 56 -|**1**|**V+**|Switching voltage (up to 55V, max 2A) 57 -|**2**|**NO**|Normally open contact 58 - 59 - 60 -1. 61 -11. 62 -111. P9 – header of relay 2 63 - 64 -[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]] 65 - 66 -By default, relay 2 is used to output the “Allow charging” signal. 67 - 68 - 69 -|**Pin**|**Name**|**Description** 70 -|**1**|**V+**|Switching voltage (up to 55V, max 2A) 71 -|**2**|**NO**|Normally open contact 72 - 73 - 74 - 75 -
- 1731516685999-633.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.5 KB - Content
- 1731516942455-641.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.5 KB - Content