Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -32,6 +32,44 @@ 32 32 |**3**|**Vcs**|ADC input (current sensor output) 33 33 |**4**|**Vref**|ADC input (current sensor reference signal) 34 34 35 -P13 – header for humidity sensor 35 +== P13 – header for humidity sensor == 36 36 37 +[[image:1731516942455-641.png||data-xwiki-image-style-alignment="center"]] 38 + 39 +|**Pin**|**Name**|**Description** 40 +|**1**|**+5V**|Supply voltage 5 V, max 50 mA 41 +|**2**|**GND**|Ground 42 +|**3**|**Vhs**|ADC input (humidity sensor output) 43 +|**4**|**Vts**|ADC input (temperature sensor output) 44 + 45 + 46 +1. 47 +11. 48 +111. P8 – header of relay 1 49 + 50 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]] 51 + 52 +By default, relay 1 is used to control the discharging contactor. 53 + 54 + 55 +|**Pin**|**Name**|**Description** 56 +|**1**|**V+**|Switching voltage (up to 55V, max 2A) 57 +|**2**|**NO**|Normally open contact 58 + 59 + 60 +1. 61 +11. 62 +111. P9 – header of relay 2 63 + 64 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]] 65 + 66 +By default, relay 2 is used to output the “Allow charging” signal. 67 + 68 + 69 +|**Pin**|**Name**|**Description** 70 +|**1**|**V+**|Switching voltage (up to 55V, max 2A) 71 +|**2**|**NO**|Normally open contact 72 + 73 + 74 + 37 37