... ... @@ -32,6 +32,44 @@
32 32  |**3**|**Vcs**|ADC input (current sensor output)
33 33  |**4**|**Vref**|ADC input (current sensor reference signal)
34 34  
35 -P13 – header for humidity sensor
35 +== P13 – header for humidity sensor ==
36 36  
37 +[[image:1731516942455-641.png||data-xwiki-image-style-alignment="center"]]
38 +
39 +|**Pin**|**Name**|**Description**
40 +|**1**|**+5V**|Supply voltage 5 V, max 50 mA
41 +|**2**|**GND**|Ground
42 +|**3**|**Vhs**|ADC input (humidity sensor output)
43 +|**4**|**Vts**|ADC input (temperature sensor output)
44 +
45 +
46 +1.
47 +11.
48 +111. P8 – header of relay 1
49 +
50 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]]
51 +
52 +By default, relay 1 is used to control the discharging contactor.
53 +
54 +
55 +|**Pin**|**Name**|**Description**
56 +|**1**|**V+**|Switching voltage (up to 55V, max 2A)
57 +|**2**|**NO**|Normally open contact
58 +
59 +
60 +1.
61 +11.
62 +111. P9 – header of relay 2
63 +
64 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]]
65 +
66 +By default, relay 2 is used to output the “Allow charging” signal.
67 +
68 +
69 +|**Pin**|**Name**|**Description**
70 +|**1**|**V+**|Switching voltage (up to 55V, max 2A)
71 +|**2**|**NO**|Normally open contact
72 +
73 +
74 +