... ... @@ -1,15 +1,30 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 +== Safety rules ==
5 +
6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS.
7 +
8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 +
10 +(% class="box errormessage" %)
11 +(((
12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 +)))
14 +
15 +(% class="box errormessage" %)
16 +(((
17 +The system is not designed to operate with batteries whose total voltage exceeds 1200 V.
18 +)))
19 +
4 4  == Installation procedure ==
5 5  
6 6  Overall and mounting dimensions of the BMS Main 2.1 are shown below.
7 7  
8 -[[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]]
9 9  
10 10  (% style="width:494px" %)
11 11  |**Parameter**|(% style="width:178px" %)**Value**
12 -|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 32
27 +|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 17
13 13  |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114
14 14  |Mounting holes|(% style="width:178px" %)M3
15 15  
... ... @@ -92,8 +92,10 @@
92 92  |**1**|**V+**|Switching voltage (up to 55V, max 3A)
93 93  |**2**|**NO**|Normally open contact
94 94  
95 -Contactor
110 +Contactor connection example for all relays:
96 96  
112 +[[image:1741619814065-850.png||height="189" width="252"]]
113 +
97 97  === P9 – header of relay 2 ===
98 98  
99 99  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
... ... @@ -106,6 +106,8 @@
106 106  |**1**|**V+**|Switching voltage (up to 55V, max 3A)
107 107  |**2**|**NO**|Normally open contact
108 108  
126 +Contactor connection example: see relay 1.
127 +
109 109  === P6 – header of relay 3 ===
110 110  
111 111  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
... ... @@ -119,6 +119,8 @@
119 119  up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
120 120  |**2**|**NO**|Normally open contact
121 121  
141 +Contactor connection example: see relay 1.
142 +
122 122  === P7 – header of relay 4 ===
123 123  
124 124  Receptacle Housing: Molex 39012020. Terminals: Molex 5556
... ... @@ -132,6 +132,8 @@
132 132  up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c)
133 133  |**2**|**NO**|Normally open contact
134 134  
156 +Contactor connection example: see relay 1.
157 +
135 135  === P14 – header for CAN and RS-485 interfaces ===
136 136  
137 137  Receptacle Housing: Molex 430250600. Terminals: Molex 43030
1741619700532-367.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +14.1 KB
Content
1741619814065-850.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +15.1 KB
Content
1741620022836-867.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +13.3 KB
Content