Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,15 +1,30 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +(% class="box errormessage" %) 11 +((( 12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 13 +))) 14 + 15 +(% class="box errormessage" %) 16 +((( 17 +The system is not designed to operate with batteries whose total voltage exceeds 1200 V. 18 +))) 19 + 4 4 == Installation procedure == 5 5 6 6 Overall and mounting dimensions of the BMS Main 2.1 are shown below. 7 7 8 -[[image:1732198397369-222.png||data-xwiki-image-style-alignment="center" height="393" width="556"]] 9 9 10 10 (% style="width:494px" %) 11 11 |**Parameter**|(% style="width:178px" %)**Value** 12 -|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 3227 +|Overall dimensions (length × width × height), mm|(% style="width:178px" %)120 × 120 × 17 13 13 |Mounting dimensions (length × width), mm|(% style="width:178px" %)114 × 114 14 14 |Mounting holes|(% style="width:178px" %)M3 15 15 ... ... @@ -92,8 +92,10 @@ 92 92 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 93 93 |**2**|**NO**|Normally open contact 94 94 95 -Contactor 110 +Contactor connection example for all relays: 96 96 112 +[[image:1741619814065-850.png||height="189" width="252"]] 113 + 97 97 === P9 – header of relay 2 === 98 98 99 99 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -106,6 +106,8 @@ 106 106 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 107 107 |**2**|**NO**|Normally open contact 108 108 126 +Contactor connection example: see relay 1. 127 + 109 109 === P6 – header of relay 3 === 110 110 111 111 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -119,6 +119,8 @@ 119 119 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 120 120 |**2**|**NO**|Normally open contact 121 121 141 +Contactor connection example: see relay 1. 142 + 122 122 === P7 – header of relay 4 === 123 123 124 124 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -132,6 +132,8 @@ 132 132 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 133 133 |**2**|**NO**|Normally open contact 134 134 156 +Contactor connection example: see relay 1. 157 + 135 135 === P14 – header for CAN and RS-485 interfaces === 136 136 137 137 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
- 1741619700532-367.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.1 KB - Content
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.1 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.3 KB - Content