Changes for page 2. Installation and connection
Last modified by Admin on 2025/07/15 17:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,24 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 11 + 12 +(% class="box warningmessage" %) 13 +((( 14 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 15 +))) 16 + 17 +(% class="box errormessage" %) 18 +((( 19 +**The system is not designed to operate with batteries whose total voltage exceeds 1200 V.** 20 +))) 21 + 4 4 == Installation procedure == 5 5 6 6 Overall and mounting dimensions of the BMS Main 2.1 are shown below. ... ... @@ -92,8 +92,10 @@ 92 92 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 93 93 |**2**|**NO**|Normally open contact 94 94 95 -Contactor 113 +Contactor connection example for all relays: 96 96 115 +[[image:1741619814065-850.png||height="189" width="252"]] 116 + 97 97 === P9 – header of relay 2 === 98 98 99 99 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -106,6 +106,8 @@ 106 106 |**1**|**V+**|Switching voltage (up to 55V, max 3A) 107 107 |**2**|**NO**|Normally open contact 108 108 129 +Contactor connection example: see relay 1. 130 + 109 109 === P6 – header of relay 3 === 110 110 111 111 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -119,6 +119,8 @@ 119 119 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 120 120 |**2**|**NO**|Normally open contact 121 121 144 +Contactor connection example: see relay 1. 145 + 122 122 === P7 – header of relay 4 === 123 123 124 124 Receptacle Housing: Molex 39012020. Terminals: Molex 5556 ... ... @@ -132,6 +132,8 @@ 132 132 up to 8A (board rev. 2.1b), up to 3A (board rev. 2.1c) 133 133 |**2**|**NO**|Normally open contact 134 134 159 +Contactor connection example: see relay 1. 160 + 135 135 === P14 – header for CAN and RS-485 interfaces === 136 136 137 137 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
- 1741619700532-367.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.1 KB - Content
- 1741619814065-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.1 KB - Content
- 1741620022836-867.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.3 KB - Content